Finger-Stick Whole Blood HIV-1/-2 Home-Use Tests Are More Sensitive than Oral Fluid-Based In-Home HIV Tests
نویسندگان
چکیده
BACKGROUND Several countries have recently recommended the expansion of anti-human immunodeficiency virus (HIV) antibody testing, including self-testing with rapid tests using oral fluid (OF). Several tests have been proposed for at-home use, but their diagnostic accuracy has not been fully evaluated. OBJECTIVE To evaluate the performance of 5 rapid diagnostic tests for the detection of anti-HIV-1/2 antibodies, with 4 testing OF and 1 testing whole blood. METHODS Prospective multi-center study in France. HIV-infected adults and HIV-uninfected controls were systematically screened with 5 at-home HIV tests using either OF or finger-stick blood (FSB) specimens. Four OF tests (OraQuick Advance Rapid HIV-1/2, Chembio DPP HIV 1/2 Assay, test A, and test B) and one FSB test (Chembio Sure Check HIV1/2 Assay) were performed by trained health workers and compared with laboratory tests. RESULTS In total, 179 HIV-infected patients (M/F sex ratio: 1.3) and 60 controls were included. Among the HIV-infected patients, 67.6% had an undetectable HIV viral load in their plasma due to antiretroviral therapy. Overall, the sensitivities of the OF tests were 87.2%, 88.3%, 58.9%, and 28% (for OraQuick, DPP, test A, and test B, respectively) compared with 100% for the FSB test Sure Check (p<0.0001 for all comparisons). The OraQuick and DPP OF tests' sensitivities were significantly lower than that of the FSB-based Sure Check (p<0.05). The sensitivities of the OF tests increased among the patients with a detectable HIV viral load (>50 copies/mL), reaching 94.8%, 96.5%, 90%, and 53.1% (for OraQuick, DPP, test A, and test B, respectively). The specificities of the four OF tests were 98.3%, 100%, 100%, and 87.5%, respectively, compared with 100% for the FSB test. CONCLUSION An evaluation of candidates for HIV self-testing revealed unexpected differences in performance of the rapid tests: the FSB test showed a far greater reliability than OF tests.
منابع مشابه
Sensitivity of Five Rapid HIV Tests on Oral Fluid or Finger-Stick Whole Blood: A Real-Time Comparison in a Healthcare Setting
BACKGROUND Health authorities in several countries recently recommended the expansion of human immunodeficiency virus (HIV) antibody testing, including the use of rapid tests. Several HIV rapid tests are now licensed in Europe but their sensitivity on total blood and/or oral fluid in routine healthcare settings is not known. METHODS AND FINDINGS 200 adults with documented HIV-1 (n=194) or HIV...
متن کاملFalse-positive oral fluid rapid HIV tests--New York City, 2005-2008.
The New York City Department of Health and Mental Hygiene (NYC DOHMH) operates 10 sexually transmitted disease (STD) walk-in clinics offering various free services, including confidential or anonymous testing for human immunodeficiency virus (HIV). In January 2004, the STD clinics introduced on-site rapid HIV testing of finger-stick whole-blood specimens using the OraQuick(R) brand test (OraSur...
متن کاملEvaluation of Diagnostic Accuracy, Feasibility and Client Preference for Rapid Oral Fluid-Based Diagnosis of HIV Infection in Rural India
BACKGROUND Oral fluid-based rapid tests are promising for improving HIV diagnosis and screening. However, recent reports from the United States of false-positive results with the oral OraQuick ADVANCE HIV1/2 test have raised concerns about their performance in routine practice. We report a field evaluation of the diagnostic accuracy, client preference, and feasibility for the oral fluid-based O...
متن کاملFalse-negative HIV tests using oral fluid tests in children taking antiretroviral therapy from Harare, Zimbabwe
INTRODUCTION Rapid diagnostic tests (RDT) for HIV infection have high sensitivity and specificity, but in the setting of longstanding antiretroviral therapy (ART), can give false results that can lead to misinterpretation, confusion and inadequate management. The objective of this study was to evaluate the proportion of falsely negative results of a RDT performed on oral fluid in HIV-infected c...
متن کاملInvestigation of False Positive Results with an Oral Fluid Rapid HIV-1/2 Antibody Test
BACKGROUND In March 2004, the OraQuick rapid HIV antibody test became the first rapid HIV test approved by the US Food and Drug Administration for use on oral fluid specimens. Test results are available in 20 minutes, and the oral fluid test is non-invasive. From August 2004-June 2005, we investigated a sudden increase in false-positive results occurring in a performance study of OraQuick oral-...