Routine pulse oximetry during methacholine challenges is unnecessary for safety.
نویسندگان
چکیده
BACKGROUND Methacholine-induced bronchoconstriction is associated with significant hypoxemia, which can be assessed noninvasively by transcutaneous oxygen tension and pulse oximetry. OBJECTIVES To assess the value of the monitoring of finger pulse oximetry during routine methacholine challenges in a clinical pulmonary function laboratory with regard to both safety and the possibility that a significant fall in oxygen saturation as measured by pulse oximetry (SpO(2)) might be a useful surrogate for determining the response to methacholine. METHODS Two hundred consecutive patients undergoing diagnostic methacholine challenges in the pulmonary function laboratory of a tertiary-care, university-based referral hospital were studied. Methacholine challenges were performed by the standardized 2-min tidal breathing technique, and the DeltaFEV(1) was calculated from the lowest postsaline solution inhalation to the lowest postmethacholine inhalation value. SpO(2) was measured immediately prior to each spirogram, and the DeltaSpO(2) was measured from the lowest postsaline solution inhalation value to the lowest postmethacholine inhalation value. We examined the data for safety (ie, any SpO(2) value < 90). Based on previous reports, we used a DeltaSpO(2) of > or = 3 as significant and looked at the sensitivity, specificity, and positive and negative predictive values for DeltaSpO(2) > or = 3 vis-à-vis a fall in FEV(1) of > or = 15%. RESULTS There were 119 nonresponders (DeltaFEV(1), < 15%) and 81 responders. The baseline FEV(1) percent predicted was slightly but significantly lower in the responders (responders [+/- SD], 91.6 +/- 15%; nonresponders, 96.4 +/- 14%; p < 0.05). DeltaSpO(2) was 3.1 +/- 1.6 in the responders and 1.6 +/- 1.8 in the nonresponders (p < 0. 001). There was a single recording in one patient of SpO(2) < 90 (88). A DeltaSpO(2) > or = 3 had a sensitivity of 68%, a specificity of 73%, a positive predictive value of 63%, and negative predictive value of 77% for a fall in FEV(1) > or = 15%. CONCLUSIONS Pulse oximetry is not routinely useful for safety monitoring during methacholine challenge. DeltaSpO(2) is not helpful in predicting a positive spirometric response to methacholine. However, the negative predictive value is adequate to allow the DeltaSpO(2) to be used as an adjunct in assessing a negative result of a methacholine test in patients who have difficulty performing spirometry.
منابع مشابه
A Three-Wavelength Pulse Oximeter for Carboxyhemoglobin Determination
Pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. This paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (HbCO), by unfiltered LEDs at 660 nm, 810 nm, and 940 nm. Background information is given on the theory of pulse oximetry. Theoretical approximations and calculations w...
متن کاملPulse oximetry may lead to unnecessary hospital admissions for infants with bronchiolitis and mild hypoxaemia.
Context Viral bronchiolitis is a leading cause for infants to be admitted to hospital. Hospitalisation rates for bronchiolitis increased more than twofold between 1980 and 2000, a period during which pulse oximetry was introduced into routine practice. Practice guidelines from the American Academy of Paediatrics have stressed that oxygen is not required in otherwise stable infants with saturati...
متن کاملMethacholine challenge in preschool children: methacholine-induced wheeze versus transcutaneous oximetry.
Tracheal/chest auscultation for wheeze and transcutaneous oximetry have both been suggested as measures of outcome in bronchial provocation tests in young children. This study aimed to compare the sensitivity and safety of these two techniques as end-points for methacholine challenge in children aged <4 yrs. Seventy-two methacholine challenges were performed in 39 children aged <4 yrs with recu...
متن کاملPulse oximetry monitoring during non-sedated upper gastrointestinal endoscopy.
Fifty consecutive patients judged fit for non-sedated upper gastrointestinal endoscopy were monitored by pulse oximetry before, during and after the procedure. Transient hypoxia developed during intubation in five subjects (10%) but treatment was not required nor was the test halted. Only one patient with pre-existing respiratory problems became hypoxaemic to the extent that oxygen had to be gi...
متن کاملEvaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals
Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 118 5 شماره
صفحات -
تاریخ انتشار 2000