Number of polyethylene particles and osteolysis in total joint replacements. A quantitative study using a tissue-digestion method.
نویسندگان
چکیده
Our aim was to analyse the influence of the size, shape and number of particles on the pathogenesis of osteolysis. We obtained peri-implant tissues from 18 patients having revision surgery for aseptically loosened Freeman total knee replacements (10), Charnley total hip replacements (3) and Imperial College/London Hospital double-cup surface hip replacements (5). The size and shape of the polyethylene particles were characterised using SEM and their concentration was calculated. The results were analysed with reference to the presence of radiological osteolysis. The concentration of polyethylene particles in 6 areas with osteolysis was significantly higher than that in 12 areas without osteolysis. There were no significant differences between the size and shape of the particles in these two groups. We conclude that the most critical factor in the pathogenesis of osteolysis is the concentration of polyethylene particles accumulated in the tissue.
منابع مشابه
In vivo response to cross-linked polyethylene and polycarbonate-urethane particles.
This study was undertaken to examine macrophage response to polycarbonate-urethane, a proposed alternative material to polyethylene in acetabular components of total hip arthroplasty. Polyethylene wear debris from total joint replacements has been linked to osteolysis and implant lifespan. It has been shown in vitro, that polyethylene particles cleaned of endotoxin generate less of an inflammat...
متن کاملWear particles and ions from cemented and uncemented titanium-based hip prostheses—A histological and chemical analysis of retrieval material
Wear debris-induced inflammation is considered to be the main cause for periprosthetic osteolysis in total hip replacements (THR). The objective of this retrieval study was to examine the tissue reactions and exposure to metal ions and wear particles in periprosthetic tissues and blood samples from patients with titanium (Ti)-based hip prostheses that were revised due to wear, osteolysis, and/o...
متن کاملDifferential effects of oxidised and non-oxidised polyethylene particles on human monocyte/macrophages in vitro.
Sterilisation by gamma irradiation in the presence of air causes free radicals generated in polyethylene (PE) to react with oxygen, which could lead to loss of physical properties and reduction in fatigue strength. Tissue retrieved from failed total hip replacements often has large quantities of particulate PE and most particles associated with peri-implant osteolysis are oxidised. Consequently...
متن کاملReview Article: Polyethylene wear and osteolysis in total hip arthroplasty.
Polyethylene wear has been accepted as a major cause of osteolysis in total hip arthroplasty. Submicron particles, which are secondary to abrasive wear, migrate into the effective joint space and stimulate a foreign-body response resulting in bone loss which is mainly mediated by macrophages. Diagnosis depends on serial radiographic evaluation and frequent follow-up. Polyethylene wear and osteo...
متن کاملBetter Survival of Total Knee Replacement in Patients Older Than 70 Years: A Prospective Study with 8 To 12 Years Follow-Up
Background: Modern knee designs have popularized its use in younger patients due to its better performance. There remains uncertainty whether higher demands of these patients can affect implant survivorship. Purpose: To assess whether modern knee designs have provided similar results in patients younger than 70 years versus older patients. Methods: We included 203 consecutive patients (236 ...