Remnant Pacemaker Lead Tips after Lead Extractions in Pacemaker Infections

نویسندگان

  • Daehoon Kim
  • Yong-Soo Baek
  • Misol Lee
  • Jae-Sun Uhm
  • Hui-Nam Pak
  • Moon-Hyoung Lee
  • Boyoung Joung
چکیده

Complete hardware removal is recommended in the case of patients with cardiovascular implantable electronic device (CIED) infections. However, the complete extraction of chronically implanted leads is not always achieved. The outcomes and optimal management of CIED infections with retained material after lead extractions have not been elucidated. In this case report, we present five patients with CIED infections with remnant lead tips even after lead extractions. Two patients had localized pocket infections, and were managed with antibiotics for a period of more than two weeks. The other three patients had infective endocarditis, and were managed with antibiotics for a period of more than four weeks. In one patient, the lead tip migrated to the right pulmonary artery, but did not produce any symptoms or complications. Only one of five patients experienced a resurgence of an infection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pacemaker lead endocarditis with hiccups (Kalayci)

Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...

متن کامل

Pacemaker Twiddler's Syndrome

A 76-yr-old man with unipolar ventricular pacemaker, previously implanted in the right ventricular apex, presented with syncopal attack and twitching of the right pectoralis muscle. He finally was diagnosed as having Twiddler's syndrome. The patient had a pulse rate of 36/min and cannon waves in the neck veins. Chest radiography showed a dislodged pacing lead completely wrapped around the pulse...

متن کامل

The Improvement of the Atrial Flutter Rhythm upon the Removal of the Infected Permanent Pacemaker Lead

Pacemaker infection has multiple risk factors. Its presentation is most often similar to infected endocarditis and the diagnosis is made through studying blood cultures. Transesophageal echocardiography can confirm the diagnosis. The most common microorganisms are staphylococcus speciesis. As a matter of fact, complete pacemaker removal appears to be the only definite treatment. We presented a ...

متن کامل

Implantation of a leadless cardiac pacemaker for recurrent pocket infections

Infections involving cardiovascular implantable electronic devices (CIEDs) remain an unfortunate indication for repeated device-related procedures, including extractions and reimplantations. Recurrent infections involving transvenous leads and superficial device pockets may eventually lead to epicardial lead implantation and generator placement in deeper tissue planes, both of which require a m...

متن کامل

RF induced heating of pacemaker/ICD lead-tips during MRI Scans at 1.5T and 3T: evaluation in cadavers

Background Studies about the safety of MRI exams for patients with pacemakers/ICDs at 1.5T have been reported [Nazarian S., et al. Annals of internal medicine 155.7 (2011): 415-424.]. Of most concern is possible heating of the lead-tips in contact with the myocardium. Little is known about the relative safety of 3T MRI exams for these patients and in vivo lead-tip heating data is difficult, if ...