Extracting Cardiac and Respiratory Self-Gating Signals from Magnetic Resonance Imaging Data

نویسندگان

  • REBECCA HELLSTRÖM
  • TOBIAS PETERSON
  • Karen Holst
  • Andreas Sigfridsson
چکیده

2015 iii ABSTRACT Motion artefacts due to cardiac and respiratory motion present a daily challenge in cardiac Magnetic Resonance Imaging (MRI), and many different motion correction procedures are used in clinical routine imaging. To reduce motion artefacts further, patients are required to hold their breath during parts of the data acquisition, which is physically straining – especially when done repetitively. Self-Gating (SG) is a method that extracts cardiac and respiratory motion information from the MRI data in the form of signals, called SG signals, and uses them to divide the data into the specific cardiac and respiratory phases it was acquired from. This method both avoids motion artefacts and allow for free-breathing acquisition. This project's goal was to find a method for extracting cardiac and respiratory SG signals from MRI data. The data was acquired with a golden angle radial acquisition method for 3-dimensional (3D) scans. Extraction of the raw signal was tested for both raw k-space data and high temporal resolution image series, where the images were reconstructed using a sliding window reconstruction. Filters were then applied to isolate the cardiac and respiratory information, to create separate cardiac and respiratory SG signals. Thereafter trigger points marking the beginning of the cardiac and respiratory cycles were generated. The trigger points were compared against ECG and respiratory trigger points provided by the MR scanner. The conclusion was that the SG signals based on k-space data was functional on the scans from the evaluated subjects and the most effective choice of the two options, but image based SG signals may prove to be functional after further studies. ABBREVIATIONS 3D-3-dimensional BMI-Body Mass Index BPM-Beats Per Minute bSSFP-Balanced Steady-State Free-Precession, an acquisition method in MRI. ECG-Electrocardiography: a way to detect the electrical impulses that stimulates the hearts muscles FOV-Field of View, the range of the area depicted in the MR image (measured in cm). MR-Magnetic Resonance MRI-Magnetic Resonance Imaging: utilizing MR to produce an image of the body, e.g. for diagnostic purposes. RF-Radio frequent SG-Self-Gating (see section 1) TE-Echo time, a parameter in the MR scan sequence. Refers to the time from the start of the radio-frequent pulse to the time at data reading (k-space line). TR-Repetition time, a parameter in the MR scan sequence. Refers to the time between each k-space line reading. viii ix CONTENTS

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition.

A respiratory and cardiac self-gated free-breathing three-dimensional cine steady-state free precession imaging method using multiecho hybrid radial sampling is presented. Cartesian mapping of the k-space center along the slice encoding direction provides intensity-weighted position information, from which both respiratory and cardiac motions are derived. With in plan radial sampling acquired a...

متن کامل

The accuracy and effectiveness of self-gating signals in free-breathing 3D cardiac cine MRI

Background Conventional cardiac cine magnetic resonance imaging (MRI) is typically based on the segmented data acquired by breath-hold 2D balanced steady-state free procession (SSFP) pulse sequence [1]. However, the slice misregistration caused by the variation of breath holding positions could compromise the effectiveness of 2D SSFP, and breath-hold makes it difficult for pediatric patients or...

متن کامل

Whole-heart cine MRI using real-time respiratory self-gating.

Two-dimensional (2D) breath-hold cine MRI is used to assess cardiac anatomy and function. However, this technique requires cooperation from the patient, and in some cases the scan planning is complicated. Isotropic nonangulated three-dimensional (3D) cardiac MR can overcome some of these problems because it requires minimal planning and can be reformatted in any plane. However, current methods,...

متن کامل

Prospective self-gating for simultaneous compensation of cardiac and respiratory motion.

Segmented cardiac acquisitions generally require the use of an electrocardiogram (ECG) in combination with a breathhold or a respiratory navigator placed on the diaphragm. These techniques necessitate patient cooperation and increase the complexity of cardiac imaging. The ECG signal may be distorted inside the magnet by interferences from radiofrequency and gradient action. Breathhold acquisiti...

متن کامل

Preliminary investigation of respiratory self-gating for free-breathing segmented cine MRI.

Segmented cine MRI generally requires breath-holding, which can be problematic for many patients. Navigator echo techniques, particularly successful for free-breathing coronary MRA, are incompatible with the acquisition strategies and SSFP pulse sequences commonly used for cine MRI. The purpose of this work is to introduce a new self-gating technique deriving respiratory gating information dire...