Preferential increase in subendocardial perfusion produced by endothelium-dependent vasodilators.

نویسندگان

  • L R Pelc
  • G J Gross
  • D C Warltier
چکیده

The transmural distribution of myocardial blood flow across the left ventricles of anesthetized dogs was measured with radioactive microspheres during intracoronary infusion of the endothelium-dependent vasodilators acetylcholine (10 micrograms/min), adenosine triphosphate (ATP; 20 micrograms/min), and arachidonic acid (600 micrograms/min) and the endothelium-independent vasodilator nifedipine (5 micrograms/min). These compounds were administered before and after a 30 min intracoronary infusion of the phospholipase A2 inhibitor quinacrine (300 micrograms/min). Acetylcholine, ATP, and arachidonic acid produced significant (p less than .05) increases in transmural blood flow and in the ratio of subendocardial to subepicardial blood flow (endo/epi) when compared with control. Infusion of quinacrine did not affect this ratio and did not block the increase in transmural blood flow produced by each agent; however, it did block the redistribution of flow to the subendocardium. In contrast, there was no change in endo/epi during intracoronary infusion of nifedipine before and after quinacrine. These results suggest that endothelium-dependent vasodilators produce a preferential increase in subendocardial perfusion via a product of unsaturated fatty acid metabolism.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Alteration of endothelium-dependent distribution of myocardial blood flow after coronary occlusion and reperfusion.

We have previously demonstrated that intracoronary infusion of the endothelium-dependent vasodilators acetylcholine, ATP, or arachidonic acid produces a preferential increase in subendocardial blood flow in anesthetized dogs. This study was performed to assess the effects of coronary artery occlusion and reperfusion on the distribution of myocardial blood flow produced by endothelium-dependent ...

متن کامل

Effects of selected endothelium-dependent vasodilators on fetoplacental vasculature: physiological implications.

The endothelium-dependent vasodilators ACh, histamine, and bradykinin were studied in the isolated, perfused human placental cotyledon. Histamine caused a decrease in perfusion pressure that was attenuated by cimetidine. Bradykinin, at lower concentrations (10-20 to 10-14 M), produced a concentration-dependent decrease in perfusion pressure, whereas at higher concentrations it produced an incre...

متن کامل

Regional differences in endothelial function in horse lungs: possible role in blood flow distribution?

We investigated regional differences of in vitro responses of pulmonary arteries (6-mm OD) from the dorsocaudal (top) and cranioventral (bottom) lung regions to endothelium-dependent vasodilators (methacholine, bradykinin, and calcium ionophore A-23187). Methacholine relaxed endothelium-intact top vessels; however, in bottom vessels, a small relaxation preceded a profound contraction. In top ve...

متن کامل

Transmural variation in autoregulation of coronary blood flow in hyperperfused canine myocardium.

We assessed transmurally the coronary autoregulatory response to elevated perfusion pressure in 85 anesthetized, open-chest dogs. Steady state and transient flow distributions were measured with 9 ± 1 /im radioactive microspheres. Steady state distributions of myocardial blood flow were uniform transmurally (P > 0.05) at perfusion pressures of 103 ± 1 (n = 81) and 146 ± 2 (n = 34) mm Hg, wherea...

متن کامل

Neutrophil-mediated vasoconstriction and endothelial dysfunction in low-flow perfusion-reperfused cat coronary artery.

We investigated the interaction between activated cat polymorphonuclear neutrophils (PMNs) and coronary vascular endothelial cells in vitro. It was shown that 1) 90 minutes of low-flow perfusion without reperfusion had no deleterious effects on endothelium-dependent vasodilation, whereas 90 minutes of low-flow perfusion and 20 minutes of reperfusion with a blood cell-free solution induced a 20-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 76 1  شماره 

صفحات  -

تاریخ انتشار 1987