Nonlinear myocardial signal intensity correction improves quantification of contrast-enhanced first-pass MR perfusion in humans.

نویسندگان

  • Li-Yueh Hsu
  • Peter Kellman
  • Andrew E Arai
چکیده

PURPOSE To study the nonlinearity of myocardial signal intensity and gadolinium contrast concentration during first-pass perfusion MRI, and to compare quantitative perfusion estimates using nonlinear myocardial signal intensity correction. MATERIALS AND METHODS The nonlinearity of signal intensity and contrast concentration was simulated by magnetization modeling and evaluated in phantom measurements. A total of 10 healthy volunteers underwent rest and stress dual-bolus perfusion studies using an echo-planar imaging sequence at both short and long saturation-recovery delay times (TD70 and TD150). Perfusion estimates were compared before and after the correction. RESULTS The phantom data showed a linear relationship (R(2) = 1.00 and 0.99) of corrected signal intensity vs. contrast concentrations. Peak myocardial contrast concentration averaged 0.64 +/- 0.10 mmol x L(-1) at rest and 0.91 +/- 0.21 mmol x L(-1) during stress for TD70 and were similar for TD150 (P = not significant [NS]). The corrections were larger for stress than rest perfusion and larger for TD150 than TD70 studies (both P < 0.01). Perfusion estimates of TD70 and TD150 stress studies were significantly different before the correction (P < 0.01) but equivalent after the correction (P = NS). CONCLUSION The nonlinearity between signal intensity and myocardial contrast concentration in perfusion MRI can be corrected through magnetization modeling. A nonlinear correction of myocardial signal intensity is feasible and improves quantitative perfusion analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Parametric Model for Quantitative Analysis of Contrast-Enhanced First-Pass MR Myocardial Perfusion that Accounts for Gd-DTPA Interstitial Loading

Introduction: Quantitative analysis of contrast-enhanced first-pass MR myocardial perfusion is useful for the detection of coronary artery disease. Myocardial blood flow (MBF) estimated from both arterial and myocardial time signal intensity curves provides more linear dynamic range for the assessment of myocardial ischemia than using semi-quantitative indices such as upslope and contrast enhan...

متن کامل

Perfusion Phantom: An Efficient and Reproducible Method to Simulate Myocardial First-Pass Perfusion Measurements with Cardiovascular Magnetic Resonance

The aim of this article is to describe a novel hardware perfusion phantom that simulates myocardial first-pass perfusion allowing comparisons between different MR techniques and validation of the results against a true gold standard. MR perfusion images were acquired at different myocardial perfusion rates and variable doses of gadolinium and cardiac output. The system proved to be sensitive to...

متن کامل

Improved accuracy of myocardial blood flow quantification by first pass perfusion MR when corrected for steady state T1 relaxation

Background Quantification of myocardial blood flow (MBF) on firstpass dynamic contrast enhanced (DCE ) MR perfusion imaging has been performed by several different methods. However MBF estimates are dependent on the analysis model used, as the absolute concentration of the contrast agent during first pass is not known. To improve the accuracy of the MBF estimates calibration is required. We pro...

متن کامل

First-Pass Contrast-Enhanced Myocardial Perfusion MRI in Mice on a 3-T Clinical MR Scanner

First-pass contrast-enhanced myocardial perfusion MRI in rodents has so far not been possible due to the temporal and spatial resolution requirements. We developed a new first-pass perfusion MR method for rodent imaging on a clinical 3.0-T scanner (Philips Healthcare, Best, The Netherlands) that employed 10-fold k-space and time domain undersampling with constrained image reconstruction, using ...

متن کامل

Fully automated pixel-wise myocardial blood flow quantification with first-pass perfusion CMR

Methods Rest and adenosine stress perfusion imaging was performed on 17 normal volunteers. A saturation recovery SSFP dual-sequence technique was used to acquire three myocardial slices and an arterial input function (AIF) image series. A proton-density weighted image was acquired at the beginning of each series. Fully quantitative perfusion pixel maps were generated by an automated processing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 27 4  شماره 

صفحات  -

تاریخ انتشار 2008