A Practical Example of GaN-LED Failure Cause Analysis by Application of Combined Electron Microscopy Techniques
نویسندگان
چکیده
In this paper, we report a failure case of blue LEDs returned from a field application, and propose a practical way to identify the physical and structural reasons for the observed malfunction by a combination of different electron microscope techniques. Cathodoluminescence imaging and electron beam induced current (EBIC) imaging are employed in order to visualize conductive paths through the device in conjunction with subsequent energy dispersive x-ray analysis (EDS), revealing a metal deposition along cracks in the semiconductor layer which short-circuit the device. We demonstrate that the electron beam induced current imaging, in conjunction with other microscopic and analytical techniques at µm scale, is a powerful combination for clearly resolving and visualizing the cause of failure in the GaN LED chip. However, this represents a case study of a real application, which may not have been generally observed in laboratory testing environment.
منابع مشابه
A Prioritization Model for HSE Risk Assessment Using Combined Failure Mode, Effect Analysis, and Fuzzy Inference System: A Case Study in Iranian Construction Industry
The unavailability of sufficient data and uncertainty in modeling, some techniques, and decision-making processes play a significant role in many engineering and management problems. Attain to sure solutions for a problem under accurate consideration is essential. In this paper, an application of fuzzy inference system for modeling the indeterminacy involved in the problem of HSE risk assessm...
متن کاملNon-linear modeling, analysis, design and simulation of a solid state power amplifier based on GaN technology for Ku band microwave application
A new non-linear method for design and analysis of solid state power amplifiers is presented and applied to an aluminum gallium nitride, gallium nitride (AlGaN-GaN) high electron-mobility transistor (HEMTs) on silicon-carbide (SiC) substrate for Ku band (12.4 13.6 GHz) applications. With combining output power of 8 transistors, maximum output power of 46.3 dBm (42.6 W), PAE of 43% and linear ga...
متن کاملComparison of Aerobic Sporadic Bacilli Structure with Electron Microscopy
I. The existence of differences and similarities in the sur- 4. face features not only of different organisms or groups but also within given species has been demonstrated by a variety of techniques. 2. The different reactions of various organisms to the Gram stain might well be taken as one piece of evidence, the use of the electron microscop and associated preparative techniques (includi...
متن کاملPreparation and application of HMCM-22 zeolite as an efficient solid acid catalyst for the synthesis of acetals
HMCM-22 with a Si:Al molar ratio of 15:1 has been shown to effectively catalyze the synthesis of acetals with 100% selectivity by the reaction of aldehydes with methanol under reflux conditions. Platelet HMCM-22 particles were prepared by the static strategy and characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), BET tech...
متن کاملPreparation and application of HMCM-22 zeolite as an efficient solid acid catalyst for the synthesis of acetals
HMCM-22 with a Si:Al molar ratio of 15:1 has been shown to effectively catalyze the synthesis of acetals with 100% selectivity by the reaction of aldehydes with methanol under reflux conditions. Platelet HMCM-22 particles were prepared by the static strategy and characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), BET tech...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2017