A biodegradable button to augment suture attachment in rotator cuff repair.

نویسندگان

  • Jonathan T Bravman
  • Dan Guttman
  • Andrew S Rokito
  • Frederick J Kummer
  • Laith M Jazrawi
چکیده

Recent experimental studies suggest that the use of suture anchors for rotator cuff tear (RCT) repair transfers the "weak link" to the suture-tendon interface where failure occurs as the sutures cut through the tendon. The purpose of this study was to evaluate the effect of using a suture augmentation button on the fixation strength of rotator cuff tendon repair. A 1.5 cm by 2 cm defect was created in the supraspinatus tendon of seven cadaveric shoulder pairs and two suture anchors inserted in each humerus for suture attachment. For one of each pair, the defect was repaired with sutures placed in a horizontal mattress configuration. The other side was repaired with the sutures being passed through low profile, bioabsorbable buttons placed on the bursal tendon surface prior to knot tying. The supraspinatus tendon was cyclically loaded at a physiologic rate and load (33 mm/sec and 180 N, respectively). The number of loading cycles was recorded when the specimens developed 0.75 cm and 1.5 cm gaps at the repair site. The specimens were then tested to failure. Specimens in the unaugmented group developed 0.75 cm and 1.5 cm gaps at an average of 135 cycles and 362 cycles, respectively. The button augmented group developed these gaps at average of 420 cycles and 708 cycles, respectively. These differences were statistically significant (p < 0.05). The gaps progressively increased in all specimens, which eventually failed by suture cutting through tendon in all specimens. This study demonstrates that in vitro, suture augmentation with a low profile, bioabsorbable button provides significantly enhanced fixation when using suture anchors to repair torn rotator cuff tendon. This device may be a useful adjunct to current methods of rotator cuff repair.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arthroscopic bone tunnel augmentation for rotator cuff repair.

Transosseous repair of the rotator cuff has been shown to recreate the anatomic rotator cuff footprint in a secure and cost-efficient manner. However, the potential for sutures cutting through bone remains a concern with this strategy. Devices have been used successfully during open transosseous rotator cuff repair to augment the bone tunnels, potentially avoiding suture cut-out through the wea...

متن کامل

A biomechanical evaluation of suture anchors in repair of the rotator cuff.

Repair of the rotator cuff requires secure reattachment, but large chronic defects cause osteoporosis of the greater tuberosity which may then have insufficient strength to allow proper fixation of the tendon. Recently, suture anchors have been introduced, but have not been fully evaluated. We have investigated the strength of suture-to-anchor attachment, and the use of suture anchors in repair...

متن کامل

Preliminary Results of a Consecutive Series of Large & Massive Rotator Cuff Tears Treated with Arthroscopic Rotator Cuff Repairs Augmented with Extracellular Matrix

 Background: Recurrence rate of rotator cuff tears is still high despite the improvements of surgical techniques, materials used and a better knowledge of the healing process of the rotator cuff tendons. Large to massive rotator cuff tears are particularly associated with a high failure rate, especially in elderly. Augmentation of rotator cuff repairs with extracellular matrix or synthetic patc...

متن کامل

Characteristics of Rotator Cuff Repairs Revised to Shoulder Arthroplasty

Background: Successful repair of a torn rotator cuff may prevent progression to rotator cuff arthropathy. However,previous studies have shown a substantial rate of failure after rotator cuff repair and characteristics of surgicallyrepaired rotator cuffs that go on to shoulder arthroplasty have not been fully elucidated. The purpose of this study wasto determine the patient cha...

متن کامل

"Owl" Technique for All-Arthroscopic Augmentation of a Massive or Large Rotator Cuff Tear With Extracellular Matrix Graft.

Despite the vast improvement in techniques and technology for arthroscopic rotator cuff surgery, repairs of massive and large tears remain challenging because they are associated with significantly high failure rates. In recent years, patch augmentation has gained popularity as a technique to decrease these high failure rates. Arthroscopic patch augmentation of rotator cuff repair, however, is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Bulletin (Hospital for Joint Diseases (New York, N.Y.))

دوره 63 3-4  شماره 

صفحات  -

تاریخ انتشار 2006