This paper proposes a new sequential weighted least squares (SWLS) method for positron emission tomography (PET) reconstruction. The SWLS algorithm is noniterative and can be considered as equivalent to the penalized WLS (PWLS) method under certain initial conditions. However, a full implementation of SWLS is computationally intensive. To overcome this problem, we propose a simplified SWLS as a reasonable alternative to the SWLS. The performance of this SWLS method is evaluated in experiments using both simulated and clinical data. The results show that the method can be advantageously compared with the original SWLS both in computation time and reconstruction quality.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Penalized weighted least-squares image reconstruction for positron emission tomography

Presents an image reconstruction method for positron-emission tomography (PET) based on a penalized, weighted least-squares (PWLS) objective. For PET measurements that are precorrected for accidental coincidences, the author argues statistically that a least-squares objective function is as appropriate, if not more so, than the popular Poisson likelihood objective. The author proposes a simple ...

متن کامل

Penalized weighted least-squares image reconstruction for positron emission tomography - Medical Imaging, IEEE Transactions on

This paper presents an image reconstruction method for positron-emission tomography (PET) based on a penalized, weighted least-squares (PWLS) objective. For PET measurements that are precorrected for accidental coincidences, we argue statistically that a least-squares objective function is as appropriate, if not more so, than the popular Poisson likelihood objective. We propose a simple data-ba...

متن کامل

from projections. ” IEEE Trans Nucl Sci, 1976; NS-23: 1428-1432 [2] A.P. Dempster, N.M. Laird, D.B. Rubin “Maximum likelihood from incomplete data via

A maximum likelihood approach to emission image reconstruction from projections. Maximum likelihood from incomplete data via the EM algorithm. " A theoretical study of some maximum likelihood algorithms for emission and transmission tomography. Attenuation compensation of cone beam SPECT images using maximum likelihood reconstruction. Three-dimensional SPECT reconstruction of combined cone beam...

متن کامل

Optimized Image Reconstruction for Emission Tomography Using Ordered Subsets, Median Root Prior and a Web-based Interface

The main objective of this work is the development and evaluation of iterative image reconstruction (IIR) methods for multitracer dynamic positron emission tomography (mdPET) studies. The ordered subsets (OS) technique applied for the acceleration of the maximum likelihood expectation maximization (ML-EM) IIR algorithm, is here extended to include the weighted-least squares (WLS), image space r...

متن کامل

Improved Weighted Least Squares Algorithm for PET Image Reconstruction Using Iterative Coordinate Descent Algorithms

In this paper, we present an image reconstruction method for positron emission tomography (PET) based on weighted least squares objective function. Unlike a usual WLS algorithm, the proposed method, which we call it ICD-WLS, minimizes the WLS objective function using iterative coordinate descent (ICD) method in a sequence of small “hidden” data spaces. Although ICD-WLS also takes a strategy to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society

دوره 32 8  شماره 

صفحات  -

تاریخ انتشار 2008