A large area, silicon photomultiplier-based PET detector module.

نویسندگان

  • Rr Raylman
  • A Stolin
  • S Majewski
  • J Proffitt
چکیده

The introduction of silicon photomultipliers (SiPM) has facilitated construction of compact, efficient and magnetic field-hardened positron emission tomography (PET) scanners. To take full advantage of these devices, methods for using them to produce large field-of-view PET scanners are needed. In this investigation, we explored techniques to combine two SiPM arrays to form the building block for a small animal PET scanner. The module consists of a 26 × 58 array of 1.5 × 1.5mm2 LYSO elements (spanning 41 × 91mm2) coupled to two SensL SiPM arrays. The SiPMs were read out with new multiplexing electronics developed for this project. To facilitate calculation of event position with multiple SiPM arrays it was necessary to spread scintillation light amongst a number of elements with a small light guide. This method was successful in permitting identification of all detector elements, even at the seam between two SiPM arrays. Since the performance of SiPMs is enhanced by cooling, the detector module was fitted with a cooling jacket, which allowed the temperature of the device and electronics to be controlled. Testing demonstrated that the peak-to-valley contrast ratio of the light detected from the scintillation array was increased by ∼45% when the temperature was reduced from 28 °C to 16 °C. Energy resolution for 511 keV photons improved slightly from 18.8% at 28 °C to 17.8% at 16 °C. Finally, the coincidence timing resolution of the module was found to be insufficient for time-of-flight applications (∼2100 ps at 14 °C). The first use of these new modules will be in the construction of a small animal PET scanner to be integrated with a 3T clinical magnetic resonance imaging scanner.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of a 64 Channel PET Detector Using Photodiodes for Crystal Identification*

element detector module and still yield a practical design. In this paper we report results of measurements made on a 64 element detector module made with LSO scintillator crystal. We present performance results for a prototype PET detector module consisting of 64 LSO scintillator crystals (3x3x20 mm) coupled on one end to a single photomultiplier tube and on the opposite end to a 64 pixel arra...

متن کامل

Design and performance evaluation of a compact, large-area PET detector module based on silicon photomultipliers

A PET module that comprises a pair of compact, high-resolution and large-area detectors based on silicon photomultipliers (SiPM) was developed and evaluated. The detector’s effective area was 24 mm!24 mm. LYSO crystals measuring 1.9 mm!1.9 mm!10 mm and charge division circuit were employed to obtain high spatial resolution with relatively concise Front-end electronics (FEE). Initial results sho...

متن کامل

Initial results of simultaneous PET/MRI experiments with an MRI-compatible silicon photomultiplier PET scanner.

UNLABELLED The most investigated semiconductor photosensor for MRI-compatible PET detectors is the avalanche photodiode (APD). However, the silicon photomultiplier (SiPM), also called the Geiger-mode APD, is gaining attention in the development of the next generation of PET/MRI systems because the SiPM has much better performance than the APD. We have developed an MRI-compatible PET system base...

متن کامل

Development of an MR-compatible DOI-PET detector module

Department of Electrical Engineering, Tsinghua University, Beijing, China Silicon Photomultiplier (SiPM) is a promising sensor for MR-compatible PET systems. In this paper, we developed a compact 2-layer DOI-PET detector. The top layer is a 15Ã15 LYSO array, and the crystal size is 2x2x7mm. The bottom layer is a 16Ã16 array with the same size crystals. There is half-crystal offset between two l...

متن کامل

Study of Silicon Photomultipliers for Positron Emission Tomography (PET) Application

A relatively new photodetector, the silicon photomultiplier (SiPM), is well suited for PET applications. It has similar sensitivity and gain to the industry standard photomultiplier tube (PMT), but has advantages such as smaller size and insensitivity to magnetic field. These properties make this detector an active area of research in the PET field. I will study a simplified setup, comprised of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment

دوره 735  شماره 

صفحات  -

تاریخ انتشار 2014