A Case of Atypical Mucin Balls Wearing Extended Wear of Silicone Hydrogel Lens for Therapeutic Use

نویسندگان

  • Yusuke Matsuzaki
  • Hiroshi Toshida
  • Toshihiko Ohta
  • Akira Murakami
چکیده

A 25-year-old man visited our hospital showing atopic conjunctivitis and corneal shield ulcer on his left eye. Although eye drops of 0.1% of betamethasone sodium phosphate and 0.1% of hyaluronic acid ophthalmic solution were prescribed, calcific corneal opacities developed. The corrected visual acuity decreased to 6/20 in Snellen chart. After corneal epithelial exfoliation, removal of calcific corneal opacity was scrubbed with MQA soaked in 0.05 M of ethylenediaminetetraacetic acid (EDTA). After washing the eye with 200 mL of physiological saline, a silicon hydrogel lens, PureVision (balafilcon A), was inserted to obtain pain relief for the therapeutic use. At postoperative day 11, mucin balls were found between cornea and contact lens and stained by rose bengal dye. One of them was atypically larger than usual, and the major axis was approximately 1.5 mm. Wearing lens was stopped, and all of mucin balls and corneal staining were disappeared at postoperative day. Little corneal opacity remained, and visual acuity after surgery recovered to 14/20 at five months.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The association between mucin balls and corneal infiltrative events during extended contact lens wear.

PURPOSE To determine the association between mucin ball formation and corneal infiltrative events (CIEs) during continuous wear with lotrafilcon A silicone hydrogel contact lenses. METHODS Subjects (n = 205) in the Longitudinal Analysis of Silicone Hydrogel Contact Lens Study wore lotrafilcon A contact lenses for 12 months of continuous wear. The primary outcome was a CIE. Kaplan-Meier method...

متن کامل

The ocular response to extended wear of a high Dk silicone hydrogel contact lens.

PURPOSE A four-month extended wear clinical trial was conducted to compare the ocular effects of a high Dk Balafilcon A silicone hydrogel lens and a low Dk HEMA 38.6 per cent H20 soft lens. METHOD Twenty-four subjects who were adapted to daily wear of soft lenses wore a high Dk lens in one eye and a low Dk HEMA lens in the other eye for four months on an extended wear basis after one week of ...

متن کامل

Mixed infection (Pseudomonas and coagulase negative staphylococci) microbial keratitis associated with extended wear silicone hydrogel contact lens

Contact lens induced ulcerative keratitis is a serious complication which can be devastating for the patient if treatment is delayed. Extended wear is the commonest cause of microbial keratitis in contact lens wear. New extended wear silicone hydrogel contact lenses have higher oxygen transmissibility so that they can be worn continuously for 30 days. They can also be used as bandage contact le...

متن کامل

Mixed infection (Pseudomonas and coagulase negative staphylococci) microbial keratitis associated with extended wear silicone hydrogel contact lens

Contact lens induced ulcerative keratitis is a serious complication which can be devastating for the patient if treatment is delayed. Extended wear is the commonest cause of microbial keratitis in contact lens wear. New extended wear silicone hydrogel contact lenses have higher oxygen transmissibility so that they can be worn continuously for 30 days. They can also be used as bandage contact le...

متن کامل

Mixed infection (Pseudomonas and coagulase negative staphylococci) microbial keratitis associated with extended wear silicone hydrogel contact lens

Contact lens induced ulcerative keratitis is a serious complication which can be devastating for the patient if treatment is delayed. Extended wear is the commonest cause of microbial keratitis in contact lens wear. New extended wear silicone hydrogel contact lenses have higher oxygen transmissibility so that they can be worn continuously for 30 days. They can also be used as bandage contact le...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013