The automated detection of stress is a central problem for ambient assisted living solutions. The paper presents the concepts and results of two studies targeted at stress detection with a low cost heart rate sensor, a chest belt. In the device validation study ( n = 5), we compared heart rate data and other features from the belt to those measured by a gold standard device to assess the reliability of the sensor. With simple synchronization and data cleaning algorithm, we were able to select highly (>97%) correlated, low average error (2.2%) data segments of considerable length from the chest data for further processing. The protocol for the clinical study ( n = 46) included a relax phase followed by a phase with provoked mental stress, 10 minutes each. We developed a simple method for the detection of the stress using only three time-domain features of the heart rate signal. The method produced accuracy of 74.6%, sensitivity of 75.0%, and specificity of 74.2%, which is impressive compared to the performance of two state-of-the-art methods run on the same data. Since the proposed method uses only time-domain features, it can be efficiently implemented on mobile devices.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

P14: Anxiety Control Using Q-Learning

Anxiety disorders are the most common reasons for referring to specialized clinics. If the response to stress changed, anxiety can be greatly controlled. The most obvious effect of stress occurs on circulatory system especially through sweating. the electrical conductivity of skin or in other words Galvanic Skin Response (GSR) which is dependent on stress level is used; beside this parameter pe...

متن کامل

Heart Rate Measurement from the Finger Using a Low- Cost Microcontroller

This paper describes the design of a simple, low-cost microcontroller based heart rate measuring device with LCD output. Heart rate of the subject is measured from the finger using optical sensors and the rate is then averaged and displayed on a text based LCD.

متن کامل

Implementation of a Low- Cost Multi- IMU by Using Information Form of a Steady State Kalman Filter

In this paper, a homogenous multi-sensor fusion method is used to estimate the trueangular rate and acceleration with a combination of four low cost (< 10$) MEMS Inertial MeasurementUnits (IMU). An information form of steady state Kalman filter is designed to fuse the output of four lowaccuracy sensors to reduce the noise effect by the square root of the number of sensors. A hardware isimplemen...

متن کامل

Low Cost UAV-based Remote Sensing for Autonomous Wildlife Monitoring

In recent years, developments in unmanned aerial vehicles, lightweight on-board computers, and low-cost thermal imaging sensors offer a new opportunity for wildlife monitoring. In contrast with traditional methods now surveying endangered species to obtain population and location has become more cost-effective and least time-consuming. In this paper, a low-cost UAV-based remote sensing platform...

متن کامل

Unauthenticated event detection in wireless sensor networks using sensors co-coverage

Wireless Sensor Networks (WSNs) offer inherent packet redundancy since each point within the network area is covered by more than one sensor node. This phenomenon, which is known as sensors co-coverage, is used in this paper to detect unauthenticated events. Unauthenticated event broadcasting in a WSN imposes network congestion, worsens the packet loss rate, and increases the network energy con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016