Resolution in rotation measurements
نویسندگان
چکیده
The limiting resolution in optical interferometry is set by the number of photons used, with the functional dependence determined by the state of light that is prepared. We consider the problem of measuring the rotation of a beam of light about an optical axis and show how the limiting resolution depends on the total number of quanta of orbital angular momentum carried by the light beam.
منابع مشابه
Pseudo Zernike Moment-based Multi-frame Super Resolution
The goal of multi-frame Super Resolution (SR) is to fuse multiple Low Resolution (LR) images to produce one High Resolution (HR) image. The major challenge of classic SR approaches is accurate motion estimation between the frames. To handle this challenge, fuzzy motion estimation method has been proposed that replaces value of each pixel using the weighted averaging all its neighboring pixels i...
متن کاملThree-dimensional Magnetotelluric Modeling of data from Northeast of Gorgan Plain
Magnetotelluric measurements have been conducted in the period range of 0.005-128 s along five parallel east-west directed profiles including 85 sites totally in the north-eastern part of Gorgan Plain, Golestan Province, North of Iran; with the aim of exploring iodine. Distortion and dimensionality analysis of data imply the existence of a north-south elongated two-dimensional model with some l...
متن کاملEffect of Head Misalignment in Horizontal & Vertical Dimensions on the Magnification Rate of Digital Panoramic Radiography in Different Parts of the Jaws
Background and aim: Considering the widespread development of implants in dental treatment plans, linear measurements on panoramic radiography are of especial importance. In the present study we investigated the effect of head misalignment up to 15° around vertical and horizontal axes on the magnification rate of digital panoramic radiography in each part of upper and lower jaws. Materia...
متن کاملWeight Measurements by Using Simple Optical-Fiber Sensors (RESEARCH NOTE)
The use of different optical-fiber sensors for weighing measurements is Abstract described. By using three different mechanical stressing mechanisms, the operation of the fiber-to-fiber transducer systems are tested and the results are presented. Parameters such as sensitivity, hysteresis, resolution, and dynamic range are measured. A comparison of the results has shown that the sensor system m...
متن کاملFaraday rotation measurements on compact helical system by using a phase sensitive heterodyne polarimeter
A phase sensitive heterodyne polarimeter was installed on compact helical system ~CHS!. An HCN laser ~337 mm! and Schottky barrier diodes are used for the radiation source and for detection, respectively. By using a phase sensitive heterodyne scheme, the Faraday rotation angle can be measured from the phase variations caused by the phase difference between the rightand left-handed waves in the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005