How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint.

نویسندگان

  • Tammy L Haut Donahue
  • M L Hull
  • Mark M Rashid
  • Christopher R Jacobs
چکیده

In an effort to prevent degeneration of articular cartilage associated with meniscectomies, both meniscal allografts and synthetic replacements are subjects of current interest and investigation. The objectives of the current study were to (1) determine whether a transversely isotropic, linearly elastic, homogeneous material model of the meniscal tissue is necessary to achieve a normal contact pressure distribution on the tibial plateau, (2) determine which material and boundary condition (attachments) parameters affect the contact pressure distribution most strongly, and (3) set tolerances on these parameters to restore the contact pressure distribution to within a specified error. To satisfy these objectives, a finite element model of the tibio-femoral joint of a human cadaveric knee (including both menisci) was used to study the contact pressure distribution on the tibial plateau. To validate the model, the contact pressure distribution on the tibial plateau was measured experimentally in the same knee used to create the model. Within physiologically reasonable bounds on five material parameters and four attachment parameters associated with a meniscal replacement, an optimization was performed under 1200 N of compressive load on the set of nine parameters to minimize the difference between the experimental and model results. The error between the experimental and model contact variables was minimized to 5.4%. The contact pressure distribution of the tibial plateau was sensitive to the circumferential modulus, axial/radial modulus, and horn stiffness, but relatively insensitive to the remaining six parameters. Consequently, both the circumferential and axial/radial moduli are important determinants of the contact pressure distribution, and hence should be matched in the design and/or selection of meniscal replacements. In addition, during surgical implantation of a meniscal replacement, the horns should be attached with high stiffness bone plugs, and the attachments of the transverse ligament and deep medial collateral ligament should be restored to minimize changes in the contact pressure distribution, and thereby possibly prevent the degradation of articular cartilage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time dependent properties of bovine meniscal attachments: stress relaxation and creep.

It has been suggested that the success of a meniscal replacement is dependent on several factors, one of which is the secure fixation and firm attachment of the replacement to the tibial plateau [Chen, M.I., Branch, T.P., et al., 1996. Is it important to secure the horns during lateral meniscal transplantation? A cadaveric study. Arthroscopy 12(2), 174-181; Alhalki, M.M., et al., 1999. How thre...

متن کامل

A finite element model of the human knee joint for the study of tibio-femoral contact.

As a step towards developing a finite element model of the knee that can be used to study how the variables associated with a meniscal replacement affect tibio-femoral contact, the goals of this study were 1) to develop a geometrically accurate three-dimensional solid model of the knee joint with special attention given to the menisci and articular cartilage, 2) to determine to what extent bony...

متن کامل

Clinical Results of Meniscal Repair Using Submeniscal Horizontal Sutures

Background:  Parts of the implants placed over the meniscus during meniscal repair can wear down the cartilage in the contact zones and cause chronic synovitis. Placing horizontal sutures under the meniscus may overcome this potential hazard. The purpose of this prospective study was to evaluate the midterm results of arthroscopic meniscal repair using submeniscally placed out-in horizontal sut...

متن کامل

Nanoindentation of the insertional zones of human meniscal attachments into underlying bone.

The fibrocartilagenous knee menisci are situated between the femoral condyles and tibia plateau and are primarily anchored to the tibia by means of four attachments at the anterior and posterior horns. Strong fixation of meniscal attachments to the tibial plateau provide resistance to extruding forces of the meniscal body, allowing the menisci to assist in load transmission from the femur to th...

متن کامل

ارتباط میان یافته‌های کمّی شده MRI با یافته‌های بالینی و رادیوگرافی ساده در بیماران مبتلا به استئوآرتریت زانو

Background: Unlike quantified MRI, no correlation has been stated between radiologic findings and the clinical signs in patients with knee osteoarthritis. This study evaluates the relationship between quantified clinical signs including pain, restriction of movement, stiffness and structural changes with MRI and plain radiography findings. Methods: Eighty patients with knee osteoarthr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 2003