Validation of a simple model for the morphology of the T wave in unipolar electrograms.
نویسندگان
چکیده
Local unipolar electrograms (UEGs) permit assessment of local activation and repolarization times at multiple sites simultaneously. However, UEG-based indexes of local repolarization are still debated, in particular for positive T waves. Previous experimental and computer modeling studies have not been able to terminate the debate. In this study we validate a simple theoretical model of the UEG and use it to explain how repolarization statistics in the UEG relate to those in the action potential. The model reconstructs the UEG by taking the difference between an inverted local action potential and a position-independent remote signal. In normal tissue, this extremely simple model predicts T-wave morphology with surprising accuracy while explaining in a readily understandable way why the instant of repolarization is always related to the steepest upstroke of the UEG, both in positive and negative T waves, and why positive T waves are related to early repolarizing sites, whereas negative T waves are related to late repolarizing sites.
منابع مشابه
Usefulness of filtered unipolar electrogram morphology for evaluating transmurality of ablated lesions during pulmonary vein isolation
BACKGROUND Although alteration of the amplitude and morphology of bipolar electrograms is used widely as a guide of the ablation effect, there is little information concerning unipolar electrograms. The amplitude and morphology of filtered bipolar (BP) and filtered unipolar (UP) electrograms were compared during pulmonary vein isolation in patients with atrial fibrillation. METHODS BP (30-250...
متن کاملUsefulness of unipolar electrograms to detect isthmus block after radiofrequency ablation of typical atrial flutter.
BACKGROUND RS morphology of the unipolar electrogram is associated with propagation of the wave front through the exploring electrode, whereas positive uniphasic (R) unipolar electrograms are characteristic of the end of activation. METHODS AND RESULTS Unipolar electrograms were recorded in 45 consecutive patients with atrial flutter who were undergoing radiofrequency ablation (RFA). Bidirect...
متن کاملA comparison of unipolar and bipolar electrograms for cardiac pacemaker sensing.
Simultaneous unipolar and bipolar electrograms were recorded and compared from 49 pacemaker patients with bipolar endocardial electrodes. Average bipolar depolarization signal voltage equalled that of unipolar but showed greater variation. Bipolar and unipolar slew rates were equal in both mean and variance. The proximal pole voltage had little effect on the bipolar result in 8% of the cases, t...
متن کاملSimultaneous endocardial mapping in the human left ventricle using a noncontact catheter: comparison of contact and reconstructed electrograms during sinus rhythm.
BACKGROUND Catheter ablation of ventricular tachycardia is limited in part by difficulty in identifying suitable sites for ablation. A noncontact multielectrode array (MEA) has been developed that allows reconstruction of 3360 electrograms, using inverse-solution mathematics, that are superimposed onto a computer-simulated model of the endocardium. This study assesses the accuracy of timing and...
متن کاملValidation and application of empirical shear wave velocity models based on standard penetration test
Shear wave velocity is a basic engineering tool required to define dynamic properties of soils. In many instances it may be preferable to determine Vs indirectly by common in-situ tests, such as the Standard Penetration Test. Many empirical correlations based on the Standard Penetration Test are broadly classified as regression techniques. However, no rigorous procedure has been published for c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 297 2 شماره
صفحات -
تاریخ انتشار 2009