In-vivo experiments of 3D femoral shape estimation using two 2D fluoroscopic images

نویسندگان

  • Yumi Iwashita
  • Ryo Kurazume
  • Kahori Nakamura
  • Toshiyuki Okada
  • Yoshinobu Sato
  • Nobuhiko Sugano
  • Tsuyoshi Koyama
  • Tsutomu Hasegawa
چکیده

In medical diagnostic imaging, the X-ray CT scanner and the MRI system have been widely used to examine 3D shapes and internal structures of living organisms and bones. However, these apparatuses are generally large and very expensive. Since an appointment is also required before examination, these systems are not suitable for urgent fracture diagnosis in emergency treatment. However, X-ray/fluoroscopy has been widely used as traditional medical diagnosis. Therefore, the realization of the reconstruction of precise 3D shapes of living organisms or bones from a few conventional 2D fluoroscopic images might be very useful in practice, in terms of cost, labor, and radiation exposure. The present paper proposes a method by which to estimate a patientspecific 3D shape of a femur from only two fluoroscopic images using a parametric femoral model. First, we develop a parametric femoral model by the statistical analysis of 3D femoral shapes created from CT images of 56 patients. Then, the position and shape parameters of the parametric model are estimated from two 2D fluoroscopic images using a distance map constructed by the Level Set Method. Experiments using in vivo images for hip prosthesis patients are successfully carried out, and it is verified that the proposed system has practical applications. I. RECONSTRUCTION OF 3D FEMORAL SHAPE FROM TWO 2D FLUOROSCOPIC IMAGES The parametric femoral model was created by the following procedure. By applying PCA to 56 samples of 3D femoral shapes, we extracted the most significant 50 principal components, standard deviation, and corresponding principal vectors for each point of the parametric femoral model. Therefore, the general 3D shape of a femur is expressed by the parametric femoral model with an average 3D shape, several principal vectors, and several (up to 50) shape parameters. Then, the position/attitude and shape parameters of the parametric model are estimated from two 2D fluoroscopic images [1]. The 2D/3D registration algorithm utilizes the contour lines of the silhouette of the 2D image and the projected contour lines of the 3D model. After the 2D distance map from the contour lines is created using the Fast Marching Method, the parametric femoral model is placed at an arbitrary position and the 2D projection image of the 3D model is calculated. Then, contour lines of the projected image and corresponding 3D patches of the 3D model are extracted. Finally, the force which is calculated from the 2D distance map at the projected contour points is applied directly to the corresponding 3D patch, and the optimum position and the shape parameters are estimated. We conducted in vivo experiments for hip prosthesis patients. We estimated the position and 10 shape parameters from the silhouette of the femur. The precise 3D shapes of patients ’ femurs were measured precisely by CT scanner. The average errors of the estimated femoral shapes for four patients are shown in Fig.1. In these figures, “0” in the horizontal axis shows the case in which only the position is estimated without parameter estimation. The experimental results show that the average error between the estimated shape and the actual shape is approximately 0.8 mm to 1.1 mm for the in vivo experiments. One example of average, actual, and estimated shapes for Case 4 is shown in Fig.2. From this figure, we verified that the errors in the femoral head and lesser trochanter are reduced. 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reconstruction of Patient-Specific 3D Bone Surface from 2D Calibrated Fluoroscopic Images and Point Distribution Model

Reconstruction of patient-specific 3D bone surface from 2D calibrated fluoroscopic images and a point distribution model is discussed. We present a 2D/3D reconstruction scheme combining statistical extrapolation and regularized shape deformation with an iterative image-to-model correspondence establishing algorithm, and show its application to reconstruct the surface of proximal femur. The imag...

متن کامل

Automatic 2D-3D Image Matching Method for the Shoulder Joint Using Single or Dual Fluoroscopic Images

INTRODUCTION Fluoroscopic image-model registration, using either a single image or dual images, has been widely used to measure in-vivo human joint kinematics, such as the knee, hip, spine and shoulder. The critical step of this technique is the registration of the 3D joint model to the 2D images. An automatic 2D-3D image matching method has been validated as a useful and efficient method for t...

متن کامل

Prediction of in-vivo Knee Joint Kinematics using a Statistical Shape Modeling

Introduction: Using computed tomography (CT) or magnetic resonance (MR) images to construct 3D knee models has been widely used in biomedical engineering research. Statistical shape modeling (SSM) method is an alternative way to provide a fast, cost-efficient, and subject-specific knee modeling technique. Further, 3D models can be used with a Dual-Fluoroscopic Imaging System (DFIS) to study joi...

متن کامل

Unsupervised Reconstruction of a Patient-Specific Surface Model of a Proximal Femur from Calibrated Fluoroscopic Images

In this paper, we present an unsupervised 2D/3D reconstruction scheme combining a parameterized multiple-component geometrical model and a point distribution model, and show its application to automatically reconstruct a surface model of a proximal femur from a limited number of calibrated fluoroscopic images with no user intervention at all. The parameterized multiple-component geometrical mod...

متن کامل

Pharyngeal Airway: An Analysis Using 2D vs. 3D Images in Different Malocclusions

Introdouction: The aim of this study was to compare information regarding pharyngeal airway sizes in adolescent subjects with different malocclusion classes obtained from lateral cephalograms and 3–dimensional (3D) cone-beam computed tomography (CBCT) scans. Materials and methods: In this prospective cross-sectional study, CBCT scans and lateral cephalograms of 35 subjects, taken with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007