Optimizing Detection of Steroids in Wastewaters Using the Agilent 6490 Triple Quadrupole LC/MS System with iFunnel Technology

نویسنده

  • Neil Cullum
چکیده

Taking full advantage of the enhanced sensitivity of the Agilent 6490 Triple Quadrupole LC/MS System requires optimization of method parameters derived on other Triple Quadrupole platforms. Optimization of steroid analysis methods in the complex matrix of wastewater results in sensitivity as low as sub-1 ng/L (1 part per trillion).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals Authors

A method using QuEChERS sample preparation and an Agilent 6490 Triple Quadrupole LC/MS has been developed that provides rapid and sub-parts per billion (ppb) detection of synthetic yohimbine and yohimbe bark extract in dietary supplements. Using the chromatographic separation of the diastereomers of yohimbine, the synthetic compound can be distinguished from the tree bark extract. An Agilent 65...

متن کامل

Highly Sensitive CE-ESI-MS/MS for Accurate Quantitation of Drugs of Abuse in Bioanalysis Using the Agilent 6490 Triple Quadrupole LC/MS System

The combination of capillary electrophoresis and mass spectrometry (CE-MS) is particularly well suited to forensic toxicology due to its high separation efficiency, selectivity and sensitivity, short analytical time, and low solvent and sample consumption. A CE-ESI-MS/MS method was developed for the quantitation of drugs of abuse in urine samples with the highly sensitive Agilent 6490 Triple Qu...

متن کامل

Longterm Detection of Anabolic Steroid Metabolites in Urine

A method for the longterm detection of anabolic steroid metabolites in urine was developed using both the Agilent 6890N network GC system with an Agilent 5975B Series GC/MSD and the Agilent 7000 Series Triple Quadrupole GC/MS. Monitoring the sulfate conjugates of these metabolites, instead of the routine glucuronide metabolites allowed detection of methenolone for a post-administration period t...

متن کامل

Rapid Analysis of Vitamin D in Serum Using Triple Quadrupole LC/MS

A rapid method for the quantification of 25-OH D2 and 25-OH D3 in serum was developed using the Agilent 1200 Series Rapid Resolution LC (RRLC) system coupled with an Agilent 6430 Triple Quadrupole LC/MS with multimode ionization (MMI). Solid phase extraction minimizes matrix interferences and ion suppression, while enabling automation. Excellent linearity of quantification (R2 > 0.99) was obtai...

متن کامل

Adapting EPA Method 8330B for Analysis of Explosives in Water to SPE and LC/MS/MS Authors

EPA Method 8330B for trace explosives in water by HPLC was transferred from UV detection to mass spectrometry detection using the Agilent 1290 Infinity LC System coupled to the Agilent 6460 Triple Quadrupole LC/MS System using APCI negative mode. Eleven explosive compounds were analyzed with this method at trace concentrations in water samples with limits of detection at the 5–50 ng/L concentra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012