A simple ergonomic measure reduces fluoroscopy time during ERCP: A multivariate analysis

نویسندگان

  • Fahd Jowhari
  • Wilma M. Hopman
  • Lawrence Hookey
چکیده

Background and study aims Endoscopic retrograde cholangiopancreatgraphy (ERCP) carries a radiation risk to patients undergoing the procedure and the team performing it. Fluoroscopy time (FT) has been shown to have a linear relationship with radiation exposure during ERCP. Recent modifications to our ERCP suite design were felt to impact fluoroscopy time and ergonomics. This multivariate analysis was therefore undertaken to investigate these effects, and to identify and validate various clinical, procedural and ergonomic factors influencing the total fluoroscopy time during ERCP. This would better assist clinicians with predicting prolonged fluoroscopic durations and to undertake relevant precautions accordingly. Patients and methods A retrospective analysis of 299 ERCPs performed by 4 endoscopists over an 18-month period, at a single tertiary care center was conducted. All inpatients/outpatients (121 males, 178 females) undergoing ERCP for any clinical indication from January 2012 to June 2013 in the chosen ERCP suite were included in the study. Various predetermined clinical, procedural and ergonomic factors were obtained via chart review. Univariate analyses identified factors to be included in the multivariate regression model with FT as the dependent variable. Results Bringing the endoscopy and fluoroscopy screens next to each other was associated with a significantly lesser FT than when the screens were separated further (-1.4 min, P = 0.026). Other significant factors associated with a prolonged FT included having a prior ERCP (+ 1.4 min, P = 0.031), and more difficult procedures (+ 4.2 min for each level of difficulty, P < 0.001). ERCPs performed by high-volume endoscopists used lesser FT vs. low-volume endoscopists (-1.82, P = 0.015). Conclusions Our study has identified and validated various factors that affect the total fluoroscopy time during ERCP. This is the first study to show that decreasing the distance between the endoscopy and fluoroscopy screens in the ERCP suite significantly reduces the total fluoroscopy time, and therefore radiation exposure to patients and staff involved in the procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reducing radiation risks during ERCP: less is more

Quality ERCP includes safety as well as efficacy. During ERCP, safety not only refers to immediate risks to the patient such as pancreatitis, bleeding and perforation, but also includes radiation risks to both the patient and the medical providers. There are numerous factors associated with radiation risk, including proper education and use of equipment, shielding of personnel, and procedure pe...

متن کامل

A prospective analysis of factors influencing fluoroscopy time during therapeutic ERCP

BACKGROUND Fluoroscopy time (FT) in endoscopic retrograde cholangiopancreatography (ERCP) has a linear relationship with radiation exposure to endoscopist, personnel and patients. The aim of this prospective study was to investigate the factors influencing the FT during ERCP. PATIENTS AND METHODS Between January 2010 and August 2011, patients with naïve papilla undergoing therapeutic ERCP wer...

متن کامل

A novel mechanical simulator for cannulation and sphincterotomy after Billroth II or Roux-en-Y reconstruction

INTRODUCTION In patients with Billroth II (B II) or Roux-en-Y anatomy, endoscopic retrograde cholangiopancreatography (ERCP) is demanding. Here, we describe a novel simulator with simulated fluoroscopy for cannulation and sphincterotomy training in such situations. METHODS A custom-made simulation system was built based upon a common chassis of a series of previously described ERCP simulators...

متن کامل

Radio induced cancer risk during ERCP. Is it a real clinical problem?

BACKGROUND in recent years many factors have been shown to influence dose received by the patient during ERCP. Therefore it is necessary to update radio induced cancer risk. OBJECTIVES to calculate lifetime attributable risk of cancer during ERCP. To compare the risk with the most common X-ray examinations. DESIGN descriptive study with 393 consecutive ERCP performed at one center. Equipmen...

متن کامل

ERCP in cholangitis.

Navaneethan et al present elegant data examining the variables associated with 30-day readmission in patients undergoing ERCP for cholangitis. However, the methodology used for their statistical analysis deserves critique and has a crucial impact on their findings. The authors introduce the concept of “door to ERCP” time, which seems intuitively to be a powerful measure of clinical success and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017