Time-resolved immunofluorometric assay of human growth hormone.
نویسندگان
چکیده
We describe a time-resolved immunofluorometric assay (trIFMA) for human growth hormone (hGH), in which monoclonal antibody (mAb)-coated microtiter strip wells and a europium (Eu) chelate-labeled mAb are used. We compare the new trIFMA, in which two mAbs are used, with an immunoradiometric assay (IRMA) in which polyclonal antibodies are used. Serum samples (n = 185) from 36 children with various diagnoses were analyzed. In addition, 24-h profile samples (72 per child) from 39 children were analyzed. The trIFMA was more sensitive (detection limit, 0.03 mIU/L) than existing IRMAs. Both the intra- and interassay CVs were < or = 10.6% for hGH concentrations between 1 and 100 mIU/L. The trIFMA is technically simple and rapid, requires no centrifugation or separation reagent, and has a counting time of only 1 s per sample. In addition, the Eu label is nontoxic, presents no waste-disposal problems, and has a long shelf-life. Finally, the assay requires only small volumes of serum (25 muL), which is of considerable importance in pediatric use. The mAbs used for the trIFMA selectively bind the 22-kDa form of hGH, with the result that the assay detects about 80% of the amount detected by the polyclonal IRMA.
منابع مشابه
Time-resolved immunofluorometric assay of sex-hormone binding globulin.
A time-resolved immunofluorometric assay (trlFMA) for human sex-hormone binding globulin (SHBG) is described in which antibody-coated tubes or microliter strip-wells and a europium (Eu) chelate-labeled monoclonal antibody are used. The trlFMA sensitivity is similar to that of other SHBG immunoassays, and other analytical variables compare favorably with an SHBG immunoradiometric assay (IRMA) ki...
متن کاملSomatotropin as measured by a two-site time-resolved immunofluorometric assay.
To date, many of the current criteria for diagnosis of somatotropin (growth hormone, GH) deficiency have been based upon measurement of this hormone by competitive radioimmunoassay (RIA) with use of polyclonal antibodies. In recent years, however, the development of hybridoma technology has led to the generation of various monoclonal antibodies (Mabs) to GH with different affinities and epitope...
متن کاملEuropium and samarium as labels in time-resolved immunofluorometric assay of follitropin.
This time-resolved immunofluorometric assay for human follitropin involves use of europium- or samarium-labeled monoclonal antibodies, with an average incorporation ratio of 3 mol of Eu3+ or Sm3+ per mole of antibody. These lanthanide ions are bound to the antibody molecules by means of the anhydride of diethylenetriaminepentaacetic acid. The solid-phase antibody is immobilized inside polystyre...
متن کاملDouble-label time-resolved immunofluorometry of lutropin and follitropin in serum.
We describe a procedure for the simultaneous immunofluorometric assay of lutropin and follitropin in human serum, based on the use of monoclonal antibodies and of the fluorescent lanthanides Eu3+ and Tb3+. The alpha-chain-specific antibody was used as a common capture antibody on the surfaces of microtitration strips. The anti-beta-follitropin antibody was labeled with Tb3+, the anti-beta-lutro...
متن کاملTwo-site time-resolved immunofluorometric assay of human insulin.
We describe a two-site "sandwich"-type time-resolved immunofluorometric assay for human insulin, based on use of two monoclonal antibodies with different specificities. The first antibody is immobilized on the surface of microtiter plate strip wells, the other is labeled with Eu3+. Serum samples can be assayed with one incubation step; two incubation steps are required when plasma samples are a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 39 8 شماره
صفحات -
تاریخ انتشار 1993