Ascending aorta diameters measured by echocardiography using both leading edge-to-leading edge and inner edge-to-inner edge conventions in healthy volunteers.

نویسندگان

  • Denisa Muraru
  • Francesco Maffessanti
  • Gonenc Kocabay
  • Diletta Peluso
  • Lucia Dal Bianco
  • Eleonora Piasentini
  • Seena Padayattil Jose
  • Sabino Iliceto
  • Luigi P Badano
چکیده

AIMS Reference ranges of ascending aorta diameters (AAoD) for two-dimensional echocardiography (2DE) using inner edge (IE) convention are lacking, preventing the comparison of AAoD measurements by 2DE with those obtained by other imaging modalities. METHODS AND RESULTS We used harmonic imaging 2DE to prospectively study 218 healthy volunteers (56% women, 42 ± 15 years, 18-80 years). Measurements were performed at the level of aortic root (AoR), sinotubular junction (STJ), and proximal tubular portion (TAo, 1 cm from the STJ) using both leading edge (LE) and IE conventions at end-diastole and end-systole. Feasibility of AAoD measurements between end-diastole and end-systole was similar at AoR and STJ levels, but it was significantly different at TAo level (82 vs. 96%, respectively, P < 0.0001). Ascending aorta diameters indexed to height were larger in men than in women (P < 0.0001). After adjusting for the effect of gender, only age and body surface area (BSA) were independent predictors of AAoD at multivariable analysis. Average end-diastolic AoR, STJ, and TAo diameters measured using IE convention were similar between genders (17 ± 2, 15 ± 2, and 15 ± 2 mm/m(2), respectively). Corresponding AAoD measured using the LE convention were 18 ± 2, 16 ± 2, and 17 ± 4 mm/m(2), respectively. On average, the end-systolic AAoD measured using LE were 2 mm larger than those performed using IE or at end-diastole. Mean aortic wall thickness was 2.4 ± 0.8 mm. CONCLUSION End-diastolic AAoD measured using IE were significantly smaller than those obtained either using LE convention or at end-systole. Gender-specific reference values for AAoD indexed for BSA should be used to identify ascending aorta pathology.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-dimensional transthoracic echocardiographic normal reference ranges for proximal aorta dimensions: results from the EACVI NORRE study.

AIMS To report normal reference ranges for echocardiographic dimensions of the proximal aorta obtained in a large group of healthy volunteers recruited using state-of-the-art cardiac ultrasound equipment, considering different measurement conventions, and taking into account gender, age, and body size of individuals. METHODS AND RESULTS A total of 704 (mean age: 46.0 ± 13.5 years) healthy vol...

متن کامل

Comparative measurement of aortic root by transthoracic echocardiography in normal Korean population based on two different guidelines

BACKGROUND Aortic root size is an important parameter in vascular diseases and can be easily assessed by transthoracic echocardiography. However, measurements values may vary according to cardiac cycle and the definition used for edge. This study aimed to define normal values according to the measurement method specified by two different guidelines to determine the influence of the different me...

متن کامل

Impact of methodology and the use of allometric scaling on the echocardiographic assessment of the aortic root and arch: a study by the Research and Audit Sub-Committee of the British Society of Echocardiography

The aim of the study is to establish the impact of 2D echocardiographic methods on absolute values for aortic root dimensions and to describe any allometric relationship to body size. We adopted a nationwide cross-sectional prospective multicentre design using images obtained from studies utilising control groups or where specific normality was being assessed. A total of 248 participants were e...

متن کامل

Buckling Analysis of Polar Orthotropic Circular and Annular Plates of Uniform and Linearly Varying Thickness with Different Edge Conditions

This paper investigates symmetrical buckling of orthotropic circular and annular plates of continuous variable thickness. Uniform compression loading is applied at the plate outer boundary. Thickness varies linearly along radial direction. Inner edge is free, while outer edge has different boundary conditions: clamped, simply and elastically restraint against rotation. The optimized Ritz method...

متن کامل

Frequency Aanalysis of Annular Plates Having a Small Core and Guided Edges at Both Inner and Outer Boundaries

This paper deals with frequency analysis of annular plates having a small core and guided edges at both inner and outer boundaries. Using classical plate theory the governing differential equation of motion for the annular plate having a small core is derived and solved for the case of plate being guided at inner and outer edge boundaries. The fundamental frequencies for the first six modes of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European heart journal cardiovascular Imaging

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2014