Nanometer axial resolution by three-dimensional supercritical angle fluorescence microscopy.

نویسندگان

  • Christian M Winterflood
  • Thomas Ruckstuhl
  • Dorinel Verdes
  • Stefan Seeger
چکیده

We report a noninvasive fluorescence microscopy method and demonstrate nanometer resolution along the optical axis. The technique is based on the influence of the microscope slide on the angular intensity distribution of fluorescence. Axial positions are determined by measuring the proportion of light emitted below the critical angle of total internal reflection, which behaves in a classical way, and light emitted above the critical angle, which is exponentially dependent on the distance of the fluorophore from the microscope slide.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Parallel two-channel near- and far-field fluorescence microscopy.

We report a new two-channel fluorescence microscopy technique for surface-generated fluorescence. The realized fluorescence microscope allows high resolution imaging of aqueous samples. The core element of the instrument is a parabolic mirror objective that is used to collect the fluorescence at large surface angles above the critical angle of the waterglass interface. An aspheric lens, incorpo...

متن کامل

Analysis of Multi - Channel Microscopy : Spectral Self - Interference , Multi - Detector Confocal and 4 Pi Systems

Fluorescence microscopy is an important and ubiquitous tool in biological imaging due to the high specificity with which fluorescent molecules can be attached to an organism and the subsequent nondestructive in-vivo imaging allowed. Focused-light microscopies allow three-dimensional fluorescence imaging but their resolution is restricted by diffraction. This effect is particularly limiting in t...

متن کامل

Three-dimensional super-resolution imaging by stochastic optical reconstruction microscopy.

Recent advances in far-field fluorescence microscopy have led to substantial improvements in image resolution, achieving a near-molecular resolution of 20 to 30 nanometers in the two lateral dimensions. Three-dimensional (3D) nanoscale-resolution imaging, however, remains a challenge. We demonstrated 3D stochastic optical reconstruction microscopy (STORM) by using optical astigmatism to determi...

متن کامل

3D superresolution microscopy by supercritical angle detection.

We present a fundamentally new approach to 3D superresolution microscopy based on the principle of surface-generated fluorescence. This near-field fluorescence is strongly dependent on the distance of fluorophores from the coverslip and can therefore be used to estimate their axial positions. We established a robust and simple implementation of supercritical angle fluorescence detection for sin...

متن کامل

Simultaneous near-field and far-field fluorescence microscopy of single molecules.

A new microscope objective is presented for the parallel fluorescence detection below and above the critical angle of total internal reflection with single molecule sensitivity. The collection of supercritical angle fluorescence (SAF) leads to a strongly surface confined detection volume whereas the collection of undercritical angle fluorescence (UAF) allows for the observation of deeper axial ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physical review letters

دوره 105 10  شماره 

صفحات  -

تاریخ انتشار 2010