Trigger Sensitivity with Dual Mirrors

نویسنده

  • Paul Sommers
چکیده

The dual mirror technique has been proposed as a method to reduce the cost of achieving a small pixel size for a prescribed S/N sensitivity. As a byproduct, the trigger sensitivity is enhanced. This is an important consideration as moonlight threatens to reduce the detector's trigger aperture. The uorescence detector shower resolution depends critically on good angular resolution as well as the signal-to-noise ratio (S/N) as de ned in the Design Report (DR). Important design parameters are the mirror diameter D and the pixel angular width . Since S/N D/ , the signal-to-noise ratio can be increased by increasing D, decreasing , or both. For the Superman 3-eye con guration without dual mirrors, the cost optimization leads to a pixel size which is too large to allow good angular resolution. The dual mirrors technique was proposed [1] as a way to achieve the required small (virtual) pixel size with half as many PMT's as would be needed with the single mirror method. [Note: For the customary single mirror con guration, a \virtual pixel" is just a PMT. With dual mirrors, \virtual pixel" refers to the overlap of two PMT's.] Mirror diameters must increase to retain the same S/N as would pertain to a single mirror system of equal virtual pixel size. Suppose a maximum allowable virtual pixel angular width 0 is dictated by angular resolution criteria, and a minimum S 0 /N 0 is speci ed by X max resolution criteria. One can then calculate the mirror diameter D 0 which would be needed using the traditional single mirror method. What mirror diameter D is needed for each of the dual mirrors to

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gradient sensitivity reduction in current mirrors with non-rectangular layout structures

A new current mirror structure using a nonrectangular dual-drain device with a shared channel to reduce the matching sensitivity to linear parameter gradients is introduced. The new structures are compared with conventional common centroid layouts for threshold voltage gradients at all angles across the active area of a mirror. Results show that in some applications, significant improvement in ...

متن کامل

Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus

The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...

متن کامل

بررسی اثر پوشش نانودی‌اکسیدتیتانیوم بر خاصیت خود تمیز شوندگی و ضد باکتریایی آینه‌های دندانپزشکی

  Objective: Surface coating of dental mirrors using nanotechnology has been done to render them self-cleaning properties. Nano-scaled titanium dioxide particles (TiO2)show antimicrobial properties when exposed to ultra-violet (UV) light. The aim of this study was to evaluate the effect of surface coating of dental mirrors with nano titanium dioxide on their self-cleaning (from dentists’ perspe...

متن کامل

Characteristic of P-type AlAs/GaAs Bragg Mirrors Grown by MBE on (100) and (311)A Oriented Substrates

P-type GaAs/AlAs distributed Bragg mirrors have been grown using molecular beam epitaxy on (100) and (311)A GaAs substrates in a similar conditions. A comparison of I-V measurements shows that the resistance of the ungraded mirrors grown on the (311)A substrate is 35 times lower than those grown on the (100) substrate with similar structure. The effective barrier heights for both (311 )A and (1...

متن کامل

Optimization of chirped mirrors.

We demonstrate that a highly efficient global optimization of chirped mirrors can be performed with the memetic algorithm. The inherently high sensitivity of chirped-mirror characteristics to manufacturing errors can be reduced significantly by means of the stochastic quasi-gradient algorithm. The applicability of these algorithms is not limited to chirped mirrors.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1996