A new single acquisition, two-image difference method for determining MR image SNR.
نویسندگان
چکیده
A new method for computing the signal-to-noise ratio (SNR) of magnetic resonance images is presented. The proposed method is a "difference of images" based technique where two images are produced from one acquisition in which the readout direction field of view (FOV) and matrix size are doubled compared to the phase encode direction. Two "normal" unaliased FOV images are produced by splitting (undersampling) the even versus odd data points in the read direction into two separate raw data sets. After image reconstruction, conventional difference of images SNR computations are applied. [Signal defined as mean within signal producing region of interest (ROI) in one image, noise defined as standard deviation of the difference between the two images using the same signal ROI position and size, divided by sqrt(2) to account for the subtraction process.] This method combines the desirable minimal acquisition time of a single image acquisition technique and the superior noise quantification characteristics of the difference of images methodology. The proposed method is more robust against system drift than existing SNR difference of images methods because the two images are effectively acquired nearly simultaneously in time. This method is compatible with phased array coils and is useful for parallel image reconstruction analysis because it is very stable. This method produces results that can be made equivalent to, and compared with, other existing SNR methods with simple known scale factors, assuming the image noise follows theoretical expectations.
منابع مشابه
Computationally Rapid Method for Estimating SNR of Arbitrary Parallel MRI Reconstructions
Introduction: SNR is a common metric of image quality, but its calculation for parallel MRI reconstructions can be challenging. A number of methods of measuring SNR for phased array image reconstructions have been proposed, including direct SNR calculation [1], Monte Carlo based “pseudo multiple replica” SNR estimation [2] and estimation of SNR from multiple acquisitions [3]. Direct SNR calcula...
متن کاملComparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملA Bayesian approach for image denoising in MRI
Magnetic Resonance Imaging (MRI) is a notable medical imaging technique that is based on Nuclear Magnetic Resonance (NMR). MRI is a safe imaging method with high contrast between soft tissues, which made it the most popular imaging technique in clinical applications. MR Imagechr('39')s visual quality plays a vital role in medical diagnostics that can be severely corrupted by existing noise duri...
متن کاملA Novel Subsampling Method for 3D Multimodality Medical Image Registration Based on Mutual Information
Mutual information (MI) is a widely used similarity metric for multimodality image registration. However, it involves an extremely high computational time especially when it is applied to volume images. Moreover, its robustness is affected by existence of local maxima. The multi-resolution pyramid approaches have been proposed to speed up the registration process and increase the accuracy of th...
متن کاملGenerating the synthetic CT (sCT) and synthetic MR (sMR: sT1w/sT2w) images of the brain using atlas based method
Introduction: Radiation therapy planning (RTP) is one of the clinical applications in which both CT scan and MRI are used. MR and CT images are applied to determine the target volume and calculation of dose distribution, respectively. In addition, using two imaging modalities increases the department workload and cost. In this study, an algorithm was presented to create synthet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 36 2 شماره
صفحات -
تاریخ انتشار 2009