3DVIEWNIX-AVS: a software package for the separate visualization of arteries and veins in CE-MRA images.
نویسندگان
چکیده
Our earlier study developed a computerized method, based on fuzzy connected object delineation principles and algorithms, for artery and vein separation in contrast enhanced Magnetic Resonance Angiography (CE-MRA) images. This paper reports its current development-a software package-for routine clinical use. The software package, termed 3DVIEWNIX-AVS, consists of the following major operational parts: (1) converting data from DICOM3 to 3DVIEWNIX format, (2) previewing slices and creating VOI and MIP Shell, (3) segmenting vessel, (4) separating artery and vein, (5) shell rendering vascular structures and creating animations. This package has been applied to EPIX Medical Inc's CE-MRA data (AngioMark MS-325). One hundred and thirty-five original CE-MRA data sets (of 52 patients) from 6 hospitals have been processed. In all case studies, unified parameter settings produce correct artery-vein separation. The current package is running on a Pentium PC under Linux and the total computation time per study is about 3 min. The strengths of this software package are (1) minimal user interaction, (2) minimal anatomic knowledge requirements on human vascular system, (3) clinically required speed, (4) free entry to any operational stages, (5) reproducible, reliable, high quality of results, and (6) cost effective computer implementation. To date, it seems to be the only software package (using an image processing approach) available for artery and vein separation of the human vascular system for routine use in a clinical setting.
منابع مشابه
بهینه سازی نگاره های MRA مغز با استفاده از ماده کنتر است زا در میدان مغناطیسی 1.5 تسلا
Background and purpose: Selection of suitable parameters for brain MRA requires accurate measures, because the image quality depends on the location of arteries, veins and also the velocity differences of blood, taking into account the low blood flow in small veins and arteries, use of paramagnetic contrast media is recommended. Hence, in present study, we investigated the imaging optimizatio...
متن کاملValue of three-dimensional contrasted-enhanced MR angiography combined with MRI in diagnosis and treatment of cerebral arteriovenous malformations
Background Cerebral arteriovenous malformations (AVMs) are congenital vascular lesions with dilated feeding arteries and draining veins without an intervening capillary bed. Treatment is recommended for most patients because of the risk of hemorrhage, which largely dependent on the imaging information available before treatment. Objective The aim was to assess the value of three-dimensional con...
متن کاملInhance (Inflow Inversion Recovery) Non-contrast Renal MRA: Comparison with 3D Gadolinium Enhanced MRA in Clinical Patients
Purpose: Contrast-enhanced MR Angiography (CE-MRA) is a widely accepted technique for evaluation of the renal arteries; however, recent concerns regarding the development of nephrogenic systemic fibrosis (NSF) after gadolinium contrast agent administration in patients with reduced renal function have emphasized the need for robust non-contrast MRA methods. One such technique is steady state fre...
متن کاملThree-Dimensional Segmentation and Visualization of Cerebral Arteries and Veins from Simultaneously Acquired MRA and MRV based on Graph-Cuts and Vessel Enhancement Filter
Introduction Accurate segmentation and appropriate visualization of the arteries and veins in the brain improve the detection and characterization of vascular abnormality such as cerebral aneurysm, arteriovenous malformation and tumor vascularity. Traditional 2D projection display of vascular images such as minimum-intensity projection (minIP) of veins in MRV offers limited visualization of com...
متن کاملMR angiography of the spine: update.
The role of MRA, as an adjunct to conventional MR imaging of the spine and spinal cord, is evolving. The older MRA methods that have been applied to spinal vascular imaging include 2D and 3D phase contrast techniques and a derivative of 3D time-of-flight techniques with data acquired for about several minutes after gadolinium contrast injection (standard 3D CE MRA). Newer 3D gradient-echo techn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society
دوره 27 5 شماره
صفحات -
تاریخ انتشار 2003