Implantable transvenous cardioverter-defibrillators.
نویسندگان
چکیده
BACKGROUND Implantable transvenous cardioverter-defibrillators offer a significant opportunity to decrease procedural morbidity and medical costs in the care of patients with life-threatening ventricular arrhythmias who otherwise would have required a sternotomy or thoracotomy for device insertion. The purpose of this study was to examine prospectively the safety, efficacy, and limitations associated with the use of a transvenously implanted, tiered-therapy cardioverter-defibrillator with antitachycardia pacing function in a consecutive population of 84 ventricular fibrillation (VF) and sustained ventricular tachycardia (VT) survivors. METHODS AND RESULTS The index arrhythmia promoting transvenous cardioverter-defibrillator implantation was VF in 41 patients, VT in 27, and both VF and VT in 16. In each patient, transvenous defibrillation via a coronary sinus, a right ventricular, a superior vena caval, and/or a subcutaneous chest patch lead system was attempted. The pulsing methods used include two-electrode single-pathway pulsing or three-electrode dual-pathway simultaneous or sequential pulsing. A transvenous cardioverter-defibrillator was inserted if the defibrillation threshold (DFT) was < or = 20 J. Successful implantation of a transvenous cardioverter-defibrillator was possible in 80 of 84 (95%) patients. The mean implant DFT was 10.9 +/- 4.8 J. After cardioverter-defibrillator implantation, all patients were extubated in the operating room and sent to a standard telemetry ward for monitoring. No patient suffered a postoperative pulmonary complication or perioperative flurry of cardiac arrhythmias. Postoperative complications included lead dislodgments in eight, transient long thoracic nerve injury in one, asymptomatic left subclavian vein occlusion in two, asymptomatic small pericardial effusion in one, subcutaneous patch pocket hematomas in four, pulse generator pocket infection in one, and lead fracture in one. As experience was gained with the procedure, it was routine to discharge patients 3 days after surgery. The mean hospital stay was 6.0 +/- 2.4 days. Upon discharge, all patients returned to their prehospital activities including those with complications except for the patient with a pocket infection, who required intravenous antibiotic therapy. Patient survival using an intention-to-treat analysis was 98% over an 11 +/- 7-month follow-up period. During this time period, 31 of the 80 patients (39%) with transvenous lead systems were successfully treated by their device for sustained VT or VF. Antitachycardia pacing was used in 424 episodes of monomorphic VT and was successful in 371 (88%). All episodes of VF were aborted by the device. Antiarrhythmic drugs were used after device implantation in only eight of 80 patients (10%). CONCLUSIONS Transvenous cardioverter-defibrillator implantation is practical in most candidates. Implant DFTs are usually low, surgical morbidity and postoperative complications are modest, therapy of VT and VF is efficient, and survival is excellent.
منابع مشابه
Subcutaneous Versus Transvenous Implantable Defibrillator Therapy
Fro of D Re Hu an Me rec Me rel Ma OBJECTIVES This study aims to conduct a meta-analysis comparing efficacy and safety outcomes between subcutaneous implantable cardioverter-defibrillator (S-ICD) and transvenous implantable cardioverter-defibrillator
متن کاملIs defibrillation testing necessary for implantable transvenous defibrillators?: defibrillation testing is necessary at the time of implantable cardioverter defibrillator implantation.
متن کامل
Transvenous Implantable Cardioverter-Defibrillator Lead Reliability: Implications for Postmarket Surveillance
BACKGROUND As implantable cardioverter-defibrillator technology evolves, clinicians and patients need reliable performance data on current transvenous implantable cardioverter-defibrillator systems. In addition, real-world reliability data could inform postmarket surveillance strategies directed by regulators and manufacturers. METHODS AND RESULTS We evaluated Medtronic Sprint Quattro, Boston...
متن کاملIncidence and Costs Related to Lead Damage Occurring Within the First Year After a Cardiac Implantable Electronic Device Replacement Procedure.
BACKGROUND Inadvertent damage to leads for transvenous pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy defibrillators is an important complication associated with generator-replacement procedures. We sought to estimate the incidence and costs associated with transvenous lead damage following cardiac implantable electronic device replacement. METHODS ...
متن کاملTransvenous implantable cardioverter-defibrillator leads: the weakest link.
Transvenous implantable cardioverter-defibrillator (ICD) lead development was an important advance in arrhythmia management. Their evolution has been critical to the wide acceptance of ICDs for the treatment of ventricular arrhythmias and the prevention of sudden cardiac death. Indeed, it is unlikely that the 20-fold increase in annual ICD implants observed during the past 15 years would have o...
متن کاملThe Subcutaneous Implantable Cardioverter-Defibrillator: Not For All
Implantable cardioverter-defibrillators (ICDs) have a proven role in primary and secondary prevention of sudden death from ventricular arrhythmias. Transvenous ICD systems despite this proven benefit, have been plagued by lead problems including fracture, insulation breaks and recalls; and issues with transvenous access including pneumothorax and venous obstruction. Infected or fractured leads ...