Compensator-based intensity-modulated radiotherapy in head and neck cancer: our experience in achieving dosimetric parameters and their clinical correlation.

نویسندگان

  • S Nangia
  • K S Chufal
  • V Arivazhagan
  • P Srinivas
  • A Tyagi
  • D Ghosh
چکیده

AIMS To review the Batra Hospital and Medical Research Centre experience of using compensator-based intensity-modulated radiotherapy (IMRT) to treat head and neck cancer. MATERIALS AND METHODS Between October 2003 and August 2004, 18 patients underwent IMRT for head and neck cancer at our institution. IMRT was delivered using partial transmission high-resolution compensator blocks. RESULTS With a median follow-up of 13.3 months, two patients had residual disease and two failed in the gross tumour volume (GTV). The complete response rate after surgical salvage was 94.5%. Both the locoregional relapse-free and disease-free survival rates were 81.8%. The target coverage in terms of average maximum, mean and minimum dose (in Gy) delivered was 78.6, 73.5 and 58.4 to the GTV-planning target volume, 82.3, 70.9 and 47.3 to clinical target volume 1 (CTV1) and 82.9, 66.2 and 29.6 to CTV2. The dose constraint of 30 Gy to less than 50% of the contralateral parotid volume was achieved in 12 (66.7%) patients. If the dose constraint was revised to 35 Gy, at least 50% of the parotid volume was spared in 17 (94.5%) patients. On average, 75% of the contralateral parotid volume received a dose less than 35 Gy in 13 (72.3%) patients with grade I xerostomia, whereas this was 49.3% in five (27.7%) patients with grade II xerostomia, and the difference was statistically significant (P = 0.001). CONCLUSIONS In our initial experience, compensator-based IMRT is feasible with regard to target coverage and parotid volume sparing. The parotid volume dose has significant clinical implications on the grade of xerostomia. Our results invoke rethinking into the issues of the parotid volume dose constraint in our subpopulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Compensator Thickness and Field Size on Buildup factor of a Brass Compensator for Intensity- Modulated Radiation Therapy

Introduction: Radiotherapy is one of the effective methods in the treatment of cancer. In the recent methods of radiotherapy, intensity modulated radiotherapy (IMRT) technique by compensators is used. when photon beam passes the compensator, scattered photons can be generated within the compensator. The presence of scattered photons may complicate the design of compensators as...

متن کامل

Dose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer

Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...

متن کامل

Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...

متن کامل

Analysis of Dosimetric Indices for Evaluating Intensity Modulated Radiotherapy Plans of Head and Neck Cancer Patients

To characterize the radiation dose distribution in the target volume, various dosimetric indices are required which assist in making a choice of an optimum treatment plan. This study is primarily aimed at the analysis of various radiation dose indices essential for the evaluation of therapeutic plans by employing Intensity Modulated Radiotherapy (IMRT) on head and neck cancer patients. A group ...

متن کامل

Comparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)

Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients.   Materials and Methods: Co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical oncology (Royal College of Radiologists (Great Britain))

دوره 18 6  شماره 

صفحات  -

تاریخ انتشار 2006