Mathematical modeling of endovenous laser treatment (ELT)

نویسندگان

  • Serge R Mordon
  • Benjamin Wassmer
  • Jaouad Zemmouri
چکیده

BACKGROUND AND OBJECTIVES Endovenous laser treatment (ELT) has been recently proposed as an alternative in the treatment of reflux of the Great Saphenous Vein (GSV) and Small Saphenous Vein (SSV). Successful ELT depends on the selection of optimal parameters required to achieve an optimal vein damage while avoiding side effects. Mathematical modeling of ELT could provide a better understanding of the ELT process and could determine the optimal dosage as a function of vein diameter. STUDY DESIGN/MATERIALS AND METHODS The model is based on calculations describing the light distribution using the diffusion approximation of the transport theory, the temperature rise using the bioheat equation and the laser-induced injury using the Arrhenius damage model. The geometry to simulate ELT was based on a 2D model consisting of a cylindrically symmetric blood vessel including a vessel wall and surrounded by an infinite homogenous tissue. The mathematical model was implemented using the Macsyma-Pdease2D software (Macsyma Inc., Arlington, MA, USA). Damage to the vein wall for CW and single shot energy was calculated for 3 and 5 mm vein diameters. In pulsed mode, the pullback distance (3, 5 and 7 mm) was considered. For CW mode simulation, the pullback speed (1, 2, 3 mm/s) was the variable. The total dose was expressed as joules per centimeter in order to perform comparison to results already reported in clinical studies. RESULTS In pulsed mode, for a 3 mm vein diameter, irrespective of the pullback distance (2, 5 or 7 mm), a minimum fluence of 15 J/cm is required to obtain a permanent damage of the intima. For a 5 mm vein diameter, 50 J/cm (15W-2s) is required. In continuous mode, for a 3 mm and 5 mm vein diameter, respectively 65 J/cm and 100 J/cm are required to obtain a permanent damage of the vessel wall. Finally, the use of different wavelengths (810 nm or 980 nm) played only a minor influence on these results. DISCUSSION AND CONCLUSION The parameters determined by mathematical modeling are in agreement with those used in clinical practice. They confirm that thermal damage of the inner vein wall (tunica intima) is required to achieve the tissue alterations necessary in order to lead the vein to permanent occlusion. However, in order to obtain a high rate of success without adverse events, the knowledge of the vein diameter after tumescent anesthesia is recommended in order to use the optimal energy. As clearly demonstrated by our calculations, both pulsed and continuous mode operations of the laser can be efficient. An interesting observation in our model is that less amount of energy is required in pulsed mode than in continuous mode. Damaging the vein sequentially along its entire length may lead to permanent occlusion. However, the pulsed mode requires a very precise positioning of the fiber after each pullback and the duration of the treatment is much longer. For these reasons, continuous irradiation seems to be preferred by most clinicians. This model should serve as a useful tool to simulate and better understand the mechanism of action of the ELT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Pullback Speed and the Distance between the Skin and Vein on the Performance of Endovenous Laser Treatment by Numerical Simulation

Introduction: Endovenous laser treatment (ELT) is a new treatment method for the reflux of the great saphenous vein. A successful ELT is dependent on the selection of optimum parameters required to achieve optimal vein damage while avoiding side effects including skin burns. The mathematical modeling of ELT can be used to understand the process of ELT. This study was conducted to examine the ef...

متن کامل

Reply to letter to the editor re: Investigation on radiofrequency and laser (980 nm) effects after endoluminal treatment of saphenous vein insufficiency in an ex-vivo model.

We would like to thank Serge Mordon and his group for their stimulus to an important discussion, which was one of the aims of our paper to initiate. Our first series of experiments indicate that ELT leads to a wide variation in the effects on tissue within a certain treatment protocol. This may be due to a very complex mechanism of endovenous laser-induced thermal alteration. In ELT, energy lev...

متن کامل

Endovenous laser ablation for the treatment of varicose veins.

Lower extremity venous insufficiency secondary to saphenous vein insufficiency is a common medical condition that decreases a patient's quality of life. Traditionally treated with high ligation and stripping, minimally invasive procedures using endovenous thermal ablation techniques, such as endovenous laser ablation, have evolved. The use of detailed imaging and advances in the understanding o...

متن کامل

Treatment of Venous Ulcer of the Lower Leg by Endovenous Laser Ablation

Venous ulcer is the most advanced stage of chronic venous insufficiency (CVI). Its prevalence is estimated to be between 1% and 3%. Recent articles have suggested that leg ulcers with reflux in superficial veins can be treated by endovenous laser ablation (EVLA). Endovenous laser ablation of the great and/or short saphenous vein has already become the treatment of choice for varicose vein and c...

متن کامل

A retrospective study comparing endovenous laser ablation and microwave ablation for great saphenous varicose veins.

BACKGROUND Endo-venous laser or microwave ablation is a minimally invasive surgery for treating varicose veins of lower limbs. AIM The aim of our study was to determine whether endovenous microwave ablation of the greater saphenous vein was associated with better effectiveness and less complications than the endovenous laser ablation. MATERIALS AND METHODS From July 2008 to June 2011, 259 c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioMedical Engineering OnLine

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2006