Pressure-flow studies in man during the Valsalva maneuver with observations on the mechanical properties of the ascending aorta.

نویسندگان

  • J C Greenfield
  • R L Cox
  • R R Hernández
  • C Thomas
  • F W Schoonmaker
چکیده

SUMMARY The pressure-gradient technique was used to obtain continuous measurements of both blood pressure and flow in the ascending aorta of eight normal subjects who were performing a standardized Valsalva maneuver. From these recordings the beat-to-beat changes in stroke volume, peak blood flow, peripheral vascular resistance, duration of ejection, and an index of total systolic duration were calculated. Stroke volume and peak blood flow were not changed with the onset of straining (phase I), but were decreased to approximately 50% of control values immediately prior to release (phase II). During the overshoot period (phase IV) stroke volume and peak flow were increased above control levels. Both the duration of ejection and the duration of systole were shortened during straining (phase II). The concomitant changes in blood pressure in these subjects were similar to previously reported pressure recordings. An estimate of the pressure-radius relationships in the ascending aorta of these patients was obtained angiographically. The mean cross-sectional area of the ascending aorta changed by 17% during the Valsalva maneuver. Indicator-dilution technique Aortic comp Ejection period Systolic period T HE EFFECT of the Valsalva maneuver on the cardiovascular system has been of interest to circulatory physiologists for many years. In order to characterize these effects, one should know beat-to-beat values for both aortic pressure and flow. Continuous recordings of blood pressure during the Val-salva maneuver are well documented' 5; however , measurements of instantaneous flow have not previously been available because of the technical problems encountered in quantita-ting phasic aortic blood flow in the intact human subject. Consequently, alterations in blood flow during the Valsalva maneuver have either been inferred from pressure data or estimated with indicator-dilution techniques.6 d Since these methods require several seconds for completion, they cannot be used to estimate beat-to-beat changes in flow during an unsteady state. At present the pressure-gradient technique provides the only practical method for measuring instantaneous aortic blood flow in the intact human subject.8 This report presents blood pressure and flow data recorded continuously in the ascending aorta

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Manipulation of ascending aortic pressure and flow wave reflections with the Valsalva maneuver: relationship to input impedance.

Dramatic changes in the shape of pulsatile ascending aortic pressure and flow wave forms occur during the Valsalva maneuver in man. To study these changes, aortic pressure and flow signals were recorded in eight patients using a multisensor catheter. Aortic input impedance was derived during the control, strain and postrelease phases of the Valsalva maneuver. During control, well-defined minima...

متن کامل

Real-time cardiac phase contrast MRI blood flow including Valsalva and Mueller maneuver. Initial experiences

Background A high resolution real-time phase-contrast MRI flow technique was used to measure flow dynamics in the ascending aorta as well as superior vena cava. MRI technique based on undersampled radial fast low-angle shot acquisitions with phase-sensitive image reconstructions by regularized nonlinear inversion. Normal flow values as well as flow measurements during physiologic stress tests l...

متن کامل

Comparison of the effectiveness of tourniquet and Valsalva maneuver in relieving pain caused by propofol injection to induce general anesthesia: A double-blind randomized clinical trial

Introduction: Propofol is one of the most common anesthetic drugs. Painful injection with a reported prevalence of 28 to 90% in various studies is one of the problems of taking Propofol. The present study investigated the effect of performing the Valsalva maneuver and tourniquet twisting on pain intensity and hemodynamic changes. Materials and Methods: This clinical trial was performed on 105 p...

متن کامل

Bicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva

Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...

متن کامل

Study of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction

Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 35 4  شماره 

صفحات  -

تاریخ انتشار 1967