Defibrillation Threshold for Implantable Defibrillators

نویسندگان

  • Charles D. Swerdlow
  • Robert M. Kass
  • Peng-Sheng Chen
چکیده

Background The time constant of truncated exponential pulses used with implantable defibrillators is determined by the output capacitor size and defibrillation pathway resistance. The optimal capacitor size is unknown. Methods and Results This study compared defibrillation threshold (DFT) for standard 120-,uF capacitors (DFT120) and smaller 60-,gF capacitors (DFT60) at implantation of cardioverter-defibrillators in 67 patients using epicardial electrodes (15 patients) or one of four transvenous electrode configurations (52 patients). Paired comparisons of DFT60 and DFT120 were made for 44 defibrillation pathways using monophasic pulses and for 53 pathways using biphasic pulses. Truncated exponential pulses with 65% tilt were used. Pooled data from all electrode configurations showed a significant inverse correlation between pathway resistance and the ratio of stored energy DFT60 to DFT120 (monophasic pulses: r=.75, P=.0001; biphasic pulses: r=.68, P=.0001). Data from all electrode configurations formed a continuum with 120-,uF capacitors superior for low-resistance pathways and 60-,F capacitors superior for high-resistance pathways. For pathways

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Azygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement

Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.

متن کامل

Subcutaneous ICD lead position affects defibrillation threshold

Introduction Subcutaneous implantable cardioverter-defibrillators (S-ICD) provide an alternative to traditional transvenous implantable cardioverter-defibrillators (TV-ICD) and avoid complications associated with intravascular access and leads. They are highly effective in detecting and treating ventricular arrhythmias, with comparable inappropriate shock rates. Use of S-ICD is anticipated to i...

متن کامل

Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations).

BACKGROUND Implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators have relied on multiple ventricular fibrillation (VF) induction/defibrillation tests at implantation to ensure that the device can reliably sense, detect, and convert VF. The ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduc...

متن کامل

Routine tests should be challenged in cardiology.

The need for routine diagnostic tests and procedures needs to be challenged in medical practice, because of continuous pressure to reduce the costs of health care systems. If costs can be minimized by avoidance of routine tests, more sources can perhaps be directed to new advanced diagnostic and therapeutic procedures. This challenge is important particularly in cardiology, because while new di...

متن کامل

Rise in defibrillation threshold after postoperative cardiac remodeling in a patient with severe Ebstein’s anomaly

Introduction Implantable cardioverter-defibrillators (ICDs) are considered standard of care for patients with life-threatening cardiac arrhythmias. In small children and patients with venous anatomy that prohibits placement of traditional transvenous leads, nontransvenous coil positions have been used and can be characterized as epicardial, pleural, subcutaneous, or a hybrid of any of the 3 pos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005