Diagnosis of insulin autoimmune syndrome using polyethylene glycol precipitation and gel filtration chromatography with ex vivo insulin exchange
نویسندگان
چکیده
CONTEXT Insulin-binding antibodies may produce severe dysglycaemia in insulin-naïve patients ('insulin autoimmune syndrome' (IAS) or Hirata disease), while rendering routine insulin assays unreliable. OBJECTIVE To assess the performance of clinically used insulin assays and an optimal analytical approach in the context of IAS. DESIGN Observational biochemical study of selected patients with hyperinsulinaemic hypoglycaemia. PATIENTS Three patients without diabetes with recurrent spontaneous hyperinsulinaemic hypoglycaemia and 'positive' insulin antibodies. MEASUREMENTS A panel of clinically used insulin assays (Siemens ADVIA® Centaur, Siemens Immulite® 2000, DiaSorin LIAISON® XL, PE AutoDELFIA® and the Beckman Coulter Access® 2) were used before and after plasma dilution or polyethylene glycol (PEG) precipitation. Anti-insulin IgG antibodies were measured by Isletest™ -IAA ELISA. Gel filtration chromatography (GFC) was undertaken with and without preincubation of plasma with exogenous insulin. RESULTS Dilution of IAS plasma with assay-specific buffer increased insulin recovery, supporting negative immunoassay interference by antibodies. PEG precipitation of IAS plasma decreased insulin recovery using all assays except the Immulite® 2000. GFC discriminated high molecular weight and monomeric insulin, while ex vivo addition of exogenous insulin to plasma increased insulin bound to antibody, thereby improving the sensitivity of detection of insulin immunocomplexes. CONCLUSIONS Immunoprecipitation with PEG must be used with caution in screening for insulin-antibody complexes as results are assay dependent. GFC with addition of exogenous insulin can identify significant insulin immunocomplexes with enhanced sensitivity, with attendant greater clinical utility and avoidance of radiolabelled reagents.
منابع مشابه
Pseudoinsulinoma in a white man with autoimmune hypoglycemia due to anti-insulin antibodies: value of the free C-Peptide assay.
OBJECTIVES Insulin autoimmune syndrome (IAS) is an extremely rare cause of hypoglycemia, particularly in non-Asian populations. METHODS In this report, we describe a white male patient with elevated total insulin (>100.0 μIU/mL), C-peptide, and proinsulin levels who was diagnosed with IAS due to anti-insulin antibodies. He also had a small IgG κ M-protein. RESULTS We show that anti-insulin ...
متن کاملIsolation of the insulin receptor of liver and fat-cell membranes (detergent-solubilized-( 125 I)insulin-polyethylene glycol precipitation-sephadex).
Extraction of liver and fat-cell membranes with the nonionic detergent Triton X-100 prevents specific binding of (125)I-labeled insulin to these membranes. This loss of binding to particulate material is quantitatively recovered in a high-speed (300,000 x g, 2 hr) supernatant of the extract. Specific and reversible insulin binding to soluble proteins is readily demonstrable by gel filtration. A...
متن کاملRare association of insulin autoimmune syndrome with ankylosing spondylitis
UNLABELLED Insulin autoimmune syndrome (IAS) is a rare cause of hyperinsulinemic hypoglycaemia, which is known to occur in association with the use of sulfhydryl-containing drugs and autoimmune disorders. We describe a patient with hitherto an unreported association of IAS with ankylosing spondylitis. We have also performed and described a simplified method of polyethylene glycol (PEG) precipit...
متن کاملRole of Molecular Interactions and Oligomerization in Chaperone Activity of Recombinant Acr from Mycobacterium tuberculosis
Background: The chaperone activity of Mycobacterium tuberculosis Acr is an important function that helps to prevent misfolding of protein substrates inside the host, especially in conditions of hypoxia. Objectives: The aim of this study was to establish the correlation of structure and function of recombinant Acr proteins both before and after ge...
متن کاملUltrafiltration – an alternative method to polyethylene glycol precipitation for macroprolactin detection
INTRODUCTION The aim of the study was to evaluate two methods of macroprolactin (MaPRL) detection - precipitation with polyethylene glycol (PEG) and ultrafiltration and to compare these techniques with "gold standard" - gel filtration chromatography (GFC). MATERIAL AND METHODS The study was conducted on 245 patients - 45 with organic and 200 with functional hyperprolactinaemia. In all the sub...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 86 شماره
صفحات -
تاریخ انتشار 2017