Assessing of Circuit Breaker Restrike Risks Using Computer Simulation and Wavelet Analysis
نویسنده
چکیده
A breaker restrike is an abnormal arcing phenomenon, leading to a possible breaker failure. Eventually, this failure leads to interruption of the transmission and distribution of the electricity supply system until the breaker is replaced. Before 2008, there was little evidence in the literature of monitoring techniques based on restrike measurement and interpretation produced during switching of capacitor banks and shunt reactor banks in power systems. In 2008 a non-intrusive radiometric restrike measurement method and a restrike hardware detection algorithm were developed by M.S. Ramli and B. Kasztenny. However, the limitations of the radiometric measurement method are a band limited frequency response as well as limitations in amplitude determination. Current restrike detection methods and algorithms require the use of wide bandwidth current transformers and high voltage dividers. A restrike switch model using Alternative Transient Program (ATP) and Wavelet Transforms which support diagnostics are proposed. Restrike phenomena become a new diagnostic process using measurements, ATP and Wavelet Transforms for online interrupter monitoring. This research project investigates the restrike switch model Parameter „A‟ dielectric voltage gradient related to a normal and slowed case of the contact opening velocity and the escalation voltages, which can be used as a diagnostic tool for a vacuum circuit-breaker (CB) at service voltages between 11 kV and 63 kV. During current interruption of an inductive load at current quenching or chopping, a transient voltage is developed across the contact gap. The dielectric strength of the gap should rise to a point to withstand this transient voltage. If it does not, the gap will flash over, resulting in a restrike. A straight line is fitted through the voltage points at flashover of the contact gap. This is the point at which the gap voltage has reached a value that exceeds the dielectric strength of the gap. This research shows that a change in opening contact velocity of the vacuum CB produces a corresponding change in the slope of the gap escalation voltage envelope. To investigate the diagnostic process, an ATP restrike switch model was modified with contact opening velocity computation for restrike waveform signature analyses along with experimental investigations. This also enhanced a mathematical CB model with the empirical dielectric model for SF6 (sulphur hexa-fluoride) CBs at service voltages above 63 kV and a generalised dielectric curve model for 12 kV CBs. A CB
منابع مشابه
High-Voltage Circuit-Breaker Fault Diagnosis Based on Mechanical Vibration Signals
In order to guarantee the operation stability of high-voltage circuit-breaker, this paper extracts eigenvector of vibration signals based on mining of characteristic entropy of the wavelet packet obtained under the state of circuit breaker. Besides, the eigenvector of various fault samples is adopted as the input information of the BP network. After that, the author conducts training of the wel...
متن کاملInvestigating Impacts of Sustainable Repair Time and Circuit Breaker Model on Meshed Distribution Networks Reliability Assessment
Generally, the failure rate and the repair time of system components are constant parameters in reliability assessment of electric distribution systems. A failure of component is resulted from failing in the operation or overloading. In addition, there exist cases where, the repair times of components are small and tolerable from customer point of view. Thus, tolerable repair times may be overl...
متن کاملMultiresolution Based Pattern Recognition Approach for Condition Monitoring of Switchgear
A new multiresolution based pattern recognition approach is proposed for fault diagnosis of distribution switchgear. The wavelet transform is used to extract the key features from the vibration spectra following circuit breaker operation. These features are then used to plot a 2-D diagram or condition map. This map displays clearly the actual condition of the circuit breaker and it can also be ...
متن کاملAnalysis of Electric Field and Polarization of SF6 Circuit Breaker to Approach a Suitable Structure
Abstract: The application of electric field theory to widely different aspects of electrical insulation has led to more understanding the phenomena. Electric fields may be considered as the main reason for insulation failure. The purpose of this paper is to modify importance of analyzing electric field in insulation design. The SF6 circuit breaker is chosen as case study that encounters cri...
متن کاملA New Fault Diagnosis Method for High Voltage Circuit Breakers Based on Wavelet Packet and Radical Basis Function Neural Network
A new method that researching fault diagnosis of high-voltage (HV) circuit breaker (CB) is proposed. The method combines Wavelet Packet (WP) with Radical Basis Function (RBF) Neural Network (NN). Firstly, by applying the theory of WP decomposition and reconstruction, the mechanical vibration signal of CB was decomposed into different frequency bands, and the coefficients are reconstructed in th...