Influence of bicortical or monocortical anchorage on maxillary implant stability: a 15-year retrospective study of Brånemark System implants.

نویسندگان

  • C J Ivanoff
  • K Gröndahl
  • C Bergström
  • U Lekholm
  • P I Brånemark
چکیده

The present study evaluated implant survival and marginal bone loss in maxillae over a 15-year follow-up period as a function of either monocortical or bicortical implant anchorage. Of 207 standard Brånemark implants (10 mm in length) followed, 110 implants were judged to be monocortically anchored and 97 as bicortically anchored. The bicortically anchored implants failed nearly 4 times more often than the monocortical ones. Implant fractures accounted for over 80% of the observed failures and were found to affect the bicortical group almost 3 times more often. As tentative explanations, induction of increased stress and bending forces resulting from possible prosthetic misfit, presence of unfavorable arch relationships, or high occlusal tables in combination with bicortically anchored implants have been suggested, all indicating an overambitious fixation of the bicortical anchorage. Total marginal bone loss was low over the 15-year period and close to identical for the 2 groups, suggesting that the mode of cortical anchorage did not have any clinically significant influence on marginal bone remodeling.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite element analysis of mono- and bicortical mini-implant stability.

OBJECTIVES Loosening and loss rates of monocortical mini-implants are relatively high, therefore the following null hypothesis was tested: 'The local bone stress in mono and bicortically-anchored mini-implants is identical'. MATERIAL AND METHODS Anisotropic Finite Element Method (FEM) models of the mandibular bone, including teeth, periodontal ligaments, orthodontic braces, and mini-implants ...

متن کامل

Effect of screw diameter on orthodontic skeletal anchorage.

INTRODUCTION Many case reports have documented the successful use of titanium miniscrews for orthodontic anchorage. However, the literature lacks a well-controlled study examining the effect of miniscrew diameter on anchorage force resistance. The purpose of this in-vitro study was to compare the force resistance of larger-diameter monocortical miniscrews to smaller-diameter monocortical minisc...

متن کامل

Interface of unloaded titanium implants in the iliac crest, fibula, and scapula: a histomorphometric and biomechanical study in the pig.

PURPOSE Prefabrication of free vascularized fibular flaps is a 2-stage procedure for the reconstruction of maxillary and mandibular defects. The delay between prefabrication and flap transfer is 6 weeks and depends on biomechanical stability and osseointegration of the implants. The purpose of this animal study was to evaluate implant stability by measuring the removal torque values (RTVs) at 3...

متن کامل

Immediate function of Brånemark implants in the esthetic zone: a retrospective clinical study with 6 months to 4 years of follow-up.

BACKGROUND Immediate implant function is a psychological benefit for the patient and makes a substantial reduction in treatment cost possible. Currently, immediate function using Brånemark implants has become an accepted alternative for complete-arch fixed restorations in mandibles and for overdenture support for some other screw-shaped implants. Clinical documentation is lacking for other appl...

متن کامل

All-on-4 immediate-function concept with Brånemark System implants for completely edentulous maxillae: a 1-year retrospective clinical study.

BACKGROUND Immediate implant function has become an accepted treatment modality for fixed restorations in totally edentulous mandibles, whereas experience from immediate function in the edentulous maxilla is limited. PURPOSE The purpose of this study was to evaluate a protocol for immediate function (within 3 hours) of four implants (All-on-4, Nobel Biocare AB, Göteborg, Sweden) supporting a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 15 1  شماره 

صفحات  -

تاریخ انتشار 2000