Estimation of input functions from dynamic [18F]FLT PET studies of the head and neck with correction for partial volume effects
نویسندگان
چکیده
BACKGROUND We present a method for extracting arterial input functions from dynamic [18F]FLT PET images of the head and neck, directly accounting for the partial volume effect. The method uses two blood samples, for which the optimum collection times are assessed. METHODS Six datasets comprising dynamic PET images, co-registered computed tomography (CT) scans and blood-sampled input functions were collected from four patients with head and neck tumours. In each PET image set, a region was identified that comprised the carotid artery (outlined on CT images) and surrounding tissue within the voxels containing the artery. The time course of activity in the region was modelled as the sum of the blood-sampled input function and a compartmental model of tracer uptake in the surrounding tissue.The time course of arterial activity was described by a mathematical function with seven parameters. The parameters of the function and the compartmental model were simultaneously estimated, aiming to achieve the best match between the modelled and imaged time course of regional activity and the best match of the estimated blood activity to between 0 and 3 samples. The normalised root-mean-square (RMSnorm) differences and errors in areas under the curves (AUCs) between the measured and estimated input functions were assessed. RESULTS A one-compartment model of tracer movement to and from the artery best described uptake in the tissue surrounding the artery, so the final model of the input function and tissue kinetics has nine parameters to be estimated. The estimated and blood-sampled input functions agreed well when two blood samples, obtained at times between 2 and 8 min and between 8 and 60 min, were used in the estimation process (RMSnorm values of 1.1 ± 0.5 and AUC errors for the peak and tail region of the curves of 15% ± 9% and 10% ± 8%, respectively). A third blood sample did not significantly improve the accuracy of the estimated input functions. CONCLUSIONS Input functions for FLT-PET studies of the head and neck can be estimated well using a one-compartment model of tracer movement and TWO blood samples obtained after the peak in arterial activity.
منابع مشابه
In vivo imaging of cellular proliferation in renal cell carcinoma using 18F-fluorothymidine PET
Objective(s): The ability to measure cellular proliferation non-invasively in renal cell carcinoma may allow prediction of tumour aggressiveness and response to therapy. The aim of this study was to evaluate the uptake of 18Ffluorothymidine (FLT) PET in renal cell carcinoma (RCC), and to compare this to 18F-fluorodeoxyglucose (FDG), and to an immunohistochemical measure of cellular proliferatio...
متن کاملValue of Dedicated Head and Neck 18F-FDG PET/CT Protocol in Detecting Recurrent and Metastatic Lesions in Post-surgical Differentiated Thyroid Carcinoma Patients with High Serum Thyroglobulin Level and Negative 131I Whole-body Scan
Objective(s): In clinical practice, approximately 10-25% of post-surgical differentiated thyroid carcinoma (DTC) patients with high serum thyroglobulin (Tg) and negative 131I whole-body scan (WBS) have poor prognosis due to recurrent or metastatic lesions after radioactive iodine treatment. The purpose of this study was to evaluate the value of 18F-FDG PET/CT scan in DTC patients with high seru...
متن کاملEffect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis
Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...
متن کاملSpillover and partial-volume correction for image-derived input functions for small-animal 18F-FDG PET studies.
UNLABELLED We present and validate a method to obtain an input function from dynamic image data and 0 or 1 blood sample for small-animal 18F-FDG PET studies. The method accounts for spillover and partial-volume effects via a physiologic model to yield a model-corrected input function (MCIF). METHODS Image-derived input functions (IDIFs) from heart ventricles and myocardial time-activity curve...
متن کاملDynamic PET evaluation of elevated FLT level after sorafenib treatment in mice bearing human renal cell carcinoma xenograft
BACKGROUND Sorafenib, an oral multikinase inhibitor, has anti-proliferative and anti-angiogenic activities and is therapeutically effective against renal cell carcinoma (RCC). Recently, we have evaluated the tumor responses to sorafenib treatment in a RCC xenograft using [Methyl-3H(N)]-3'-fluoro-3'-deoxythythymidine ([3H]FLT). Contrary to our expectation, the FLT level in the tumor significantl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 3 شماره
صفحات -
تاریخ انتشار 2013