An evaluation of osmolality measurement by freezing point depression using micro-amounts of sample

نویسندگان

  • G. Koumantakis
  • L. E. Wyndham
چکیده

An evaluation of the Advanced micro-osmometer is presented. This instrument has been shown to have an excellent analytical precision (within-run CV = 0.59%, between-day CV = 0.58%). It is accurate over an analytical range of 0-2000 mmol/kg of osmolality shown by linearity studies and split sample correlations against vapour pressure osmometry, freezing point osmometry and an external quality assurance programme. Analytical errors due to operator technique are almost eliminated because of good instrument design. Preliminary results on whole-blood osmolality are included. The required sample size of 20 mul permits osmolality measurements on most clinical samples. It is concluded that the Advanced micro-osmometer satisfies laboratory requirements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Freezing point osmometry of milk to determine the additional water content – an issue in general quality control and German food regulation

BACKGROUND The determination of the osmolality of aqueous samples using a freezing point osmometer is a well-established, routine laboratory method. In addition to their use in clinical and pharmaceutical laboratories, freezing point osmometers are also employed in food testing laboratories. One application is the determination of the osmolality of milk. Although cow's milk is a natural product...

متن کامل

An automated osmometer.

A freezing-point apparatus, which measures osmotic pressure by determining freezingpoint depression, was modified by incorporating a slowly rotating circular tray with space for 30 sample vials, and a sample pick-up device. The instrument is designed to automatically pick up a cuvet containing a 2-mi. specimen of serum, urine, spinal fluid, or any biologic fluid, and to cool, supercool, freeze,...

متن کامل

Molecular Dynamics Simulations of Freezing Behavior of Pure Water and 14% Water-NaCl Mixture Using the Coarse-Grained Model

 We performed molecular dynamics simulations using the coarse-grained model to study the freezing behavior of pure water and 14% water-salt mixture in a wide range of temperatures for a very long time around 50 nanoseconds. For the salty water, an interface in nanoscale was used. For both systems, the f...

متن کامل

Is urinary density an adequate predictor of urinary osmolality?

BACKGROUND Urinary density (UD) has been routinely used for decades as a surrogate marker for urine osmolality (Uosm). We asked if UD can accurately estimate Uosm both in healthy subjects and in different clinical scenarios of kidney disease. METHODS UD was assessed by refractometry. Uosm was measured by freezing point depression in spot urines obtained from healthy volunteers (N = 97) and in...

متن کامل

Agreement between Different Equations to Estimate Osmolarity of Parenteral Nutrition Solutions.

BACKGROUND our aim was to measure the osmolality of several PN formulas at different component concentrations to determine if equations described in literature to calculate osmolarity accurately predict osmolalality in other experimental conditions different than these used to develop them. METHODS osmolality of 12 different types of PN solutions, 9 for central and 3 for peripheral perfusion ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 11  شماره 

صفحات  -

تاریخ انتشار 1989