Mass-produced lonophore-based fluorescent microspheres for trace level determination of lead ions.
نویسندگان
چکیده
The development and characterization of small, uniform, and mass-produced plasticized PVC-based sensing microspheres in view of rapid trace level analysis of lead ions is reported. Micrometer-sized particles obtained via an automated casting process were rendered selective for lead ions by doping them with highly selective components in a manner analogous to traditional optode sensing films. Single particles that contained the lipophilic ionophore N,N,N',N'-tetradodecyl-3-6-dioxaoctane-1-thio-8-oxodiamide (ETH 5493), the chromoionophore ETH 5418 together with a lipophilized indocarbocyanine derivative as internal reference dye (DiIC18), and lipophilic ion-exchanger sites sodium tetrakis[3,5-bistrifluoromethylphenyl]borate, yielded measurable lead responses at the low nanomolar level in pH buffered solutions. The detection limit for single particles was 3 x 10(-9) M at pH 5.7. The microspheres were fabricated via a reproducible formation of polymer droplets within a flowing aqueous phase followed by collection of spherical particles of approximately 13 microm in size. The particles were immobilized and assayed individually in a microflow cell via fluorescence microscopy. Selectivity patterns found were in agreement with those reported earlier for the lead-selective ligand ETH 5493, and all response functions were fully described by theory. In contrast to optode films that necessitated very long equilibration times and large sample volumes in diluted samples of analyte, particles exhibited extremely enhanced equilibrium response times. Thus, for lead sample concentrations at and above 5 x 10(-8) M, response times were approximately 3 min, whereas at the detection limit, complete equilibrium was recorded after just 15 min, with required sample volumes on the order of 1 mL This new class of microspheres appears to be suitable for rapid and sensitive ion detection at trace levels in environmental and biological applications.
منابع مشابه
Preconcentration of Pb(II) by Graphene Oxide with Covalently Linked Porphyrin Adsorbed on Surfactant Coated C18 before Determination by FAAS
A simple, highly sensitive, accurate and selective method for determination of trace amounts of Pb(II) in water samples is presented. A novel Graphene oxide with covalently linked porphyrin solid-phase extraction adsorbent was synthesized by covalently linked porphyrin onto the surfaces of graphite oxides. The stability of a chemically (GO-H2P) especially in concentrated hydrochloric acid was s...
متن کاملPreconcentration of Pb(II) by Graphene Oxide with Covalently Linked Porphyrin Adsorbed on Surfactant Coated C18 before Determination by FAAS
A simple, highly sensitive, accurate and selective method for determination of trace amounts of Pb(II) in water samples is presented. A novel Graphene oxide with covalently linked porphyrin solid-phase extraction adsorbent was synthesized by covalently linked porphyrin onto the surfaces of graphite oxides. The stability of a chemically (GO-H2P) especially in concentrated hydrochloric acid was s...
متن کاملDetermination of trace amounts of chromium ions in water and food samples using ligand-less solid phase extraction-based modified nano-boehmite(AlOOH)
Chromium is one of the hazardous pollutants in industrial effluents. In this study, a new nano-boehmite modified with sodium dodecyl sulphate is developed for preconcentration trace amounts of chromium ions as a prior step to its determination by flame atomic absorption spectrometry. We investigated the effect of various parameters on the recovery of the analyte ions, including pH of sample solut...
متن کاملConstruction of a Carbon Paste Electrode Based on Novel Thiolated Ligand Capped Gold Nanoparticles for Determination of Trace Amounts of Mercury(II)
In the present study, a simple electrochemical sensor for trace determination of Hg(II) ions in aqueous solutions was introduced. The proposed sensor was designed by incorporation of the 4-methyl-piperidine-carbodithioate capped gold nanoparticles (GNPs) into the carbon paste electrode (CPE), which provides a remarkably improved sensitivity for stripping voltammetric determination of Hg(II). Di...
متن کاملSimultaneous Determination of Traces of Lead and Cadmium in Various Samples by Differential Pulse Polarography after Adsorbing Their 1-(2-Pyridyazol)-2-Naphthol onto Microcrystalline Naphthalene
A highly selective, rapid and economical differential pulse polarographic method has been developed for the determination of trace amounts of cadmium and lead present together in various standard alloys and biological samples after adsorption of their 1-(2-pyridylazo)-2-naphthol complexes on microcrystalline naphthalene. Cadmium and lead complexes are equantitatively adsorbed on microcrysta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 74 20 شماره
صفحات -
تاریخ انتشار 2002