Optimized Use of the MALDI BioTyper System and the FilmArray BCID Panel for Direct Identification of Microbial Pathogens from Positive Blood Cultures.

نویسندگان

  • B Fiori
  • T D'Inzeo
  • A Giaquinto
  • G Menchinelli
  • F M Liotti
  • F de Maio
  • G De Angelis
  • G Quaranta
  • D Nagel
  • M Tumbarello
  • B Posteraro
  • M Sanguinetti
  • T Spanu
چکیده

Despite the current reliance on blood cultures (BCs), the diagnosis of bloodstream infections (BSIs) can be sped up using new technologies performed directly on positive BC bottles. Two methods (the MALDI BioTyper system and FilmArray blood culture identification [BCID] panel) are potentially applicable. In this study, we performed a large-scale clinical evaluation (1,585 microorganisms from 1,394 BSI episodes) on the combined use of the MALDI BioTyper and FilmArray BCID panel compared to a reference (culture-based) method. As a result, the causative organisms of 97.7% (1,362/1,394) of the BSIs were correctly identified by our MALDI BioTyper and FilmArray BCID-based algorithm. Specifically, 65 (5.3%) out of 1,223 monomicrobial BCs that provided incorrect or invalid identifications with the MALDI BioTyper were accurately detected by the FilmArray BCID panel; additionally, 153 (89.5%) out of 171 polymicrobial BCs achieved complete identification with the FilmArray BCID panel. Conversely, full use of the MALDI BioTyper would have resulted in the identification of only 1 causative organism in 97/171 (56.7%) of the polymicrobial cultures. By applying our diagnostic algorithm, the median time to identification was shortened (19.5 h versus 41.7 h with the reference method; P < 0.001), and the minimized use of the FilmArray BCID panel led to a significant cost savings. Twenty-six out of 31 microorganisms that could not be identified were species/genera not designed to be detected with the FilmArray BCID panel, indicating that subculture was not dispensable for a few of our BSI episodes. In summary, the fast and effective testing of BC bottles is realistically adoptable in the clinical microbiology laboratory workflow, although the usefulness of this testing for the management of BSIs remains to be established.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the BioFire® FilmArray® Blood Culture Identification Panel on positive blood cultures in a regional hospital laboratory in KwaZulu-Natal

BACKGROUND There are presently many non-culture-based methods commercially available to identify organisms and antimicrobial susceptibility from blood culture bottles. Each platform has its benefits and limitations. However, there is a need for an improved system with minimal hands-on requirements and short run times. OBJECTIVES In this study, the performance characteristics of the FilmArray®...

متن کامل

Performance of the FilmArray® blood culture identification panel utilized by non-expert staff compared with conventional microbial identification and antimicrobial resistance gene detection from positive blood cultures.

Utilization of commercially available rapid platforms for microbial identification from positive blood cultures is useful during periods of, or in laboratories with, limited expert staffing. We compared the results of the FilmArray® BCID Panel performed by non-expert technologists to those of conventional methods for organism identification performed by skilled microbiologists. Within 8 h of si...

متن کامل

FilmArray: correction of previously false-positive results by improved software.

Bloodstream infections (BSIs) are a leading cause of death and have high health care-related costs worldwide (1). Hithertopublished studies showed that receiving timely and accurate information as to the nature of the causative agent(s) and its antimicrobial susceptibilities is of the utmost importance for clinical management as well as for implementation of the optimal targeted antimicrobial t...

متن کامل

Detection of bacterial pathogens in synovial and pleural fluid with the FilmArray Blood Culture Identification System

We report the use of FilmArray Blood Culture Identification (BCID) multiplex PCR system for pathogen detection from a child with septic arthritis that Streptococcus pyogenes was identified directly from synovial fluid and a child with complicated pneumonia with pleural effusion that Streptococcus pneumoniae was identified from pleural fluid.

متن کامل

Applicability of an in-House Saponin-Based Extraction Method in Bruker Biotyper Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry System for Identification of Bacterial and Fungal Species in Positively Flagged Blood Cultures

We used an in-house saponin-based extraction method to evaluate the performance of the Bruker Biotyper matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS) system for the identification of bacteria and fungi in 405 positively flagged blood culture bottles. Results obtained from MALDI-TOF/MS were compared with those obtained using conventional phenotypic id...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 54 3  شماره 

صفحات  -

تاریخ انتشار 2016