Cerebral circulation studies using inhaled 133-xenon and the gamma camera.

نویسندگان

  • A C Klassen
  • J A Resch
  • M K Loken
  • E A Johnson
چکیده

Cerebral Circulation Studies Using Inhaled 133-Xenon and the Gamma Camera • Inhaled 133-xenon was utilized in conjunction with the Anger gamma scintillation camera to evaluate cerebral circulation in 20 asymptomatic control subjects and in 41 patients with clinical cerebrovascular disease. Sequental cerebral scintiphotos thus obtained revealed focal areas of decreased activity in 2 of 19 control subjects and in 15 of 38 patients. A computerized curve-fitting technique was used to calculate an index of cerebral blood flow ("K") by means of the 133-xenon clearance curves obtained from each half of the head. Shorter periods of 133-xenon inhalation resulted in more rapid rates of clearance. In patients with clinical cerebrovascular disease, cerebral clearance rates tended to be lower and to show more variation between the two sides of the head than in asymptomatic subjects. ADDITIONAL

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of the gamma ray spectra recorded in the use of Xenon-133 for cerebral blood flow studies.

A problem in the measurement of cerebral blood flow with 133Xenon is the presence of extra-cerebral counts in the total counts recorded with a collimated gamma ray detector looking at the brain. A method of studying qualitatively the contribution of this extra-cranial component in patients is described. This entails the sequential accumulation of gamma ray spectra recorded during the clearance ...

متن کامل

jnm / DIAGNOSTIC NUCLEAR MEDICINE

Xenon-133 and xenon-127 were compared by performing ventilation studies with both radionuclides in 19 patients with a variety of lung diseases. Assessment of the counting rate over the chest, relative to the radioactivity in the lungs, permitted the evaluation of each isotope in terms of usable photons detected by a scintillation camera with a large field of view and ap propriate collimili ion....

متن کامل

Single-photon tomographic determination of regional cerebral blood flow in epilepsy.

Using a single-photon emission computed tomographic scanner (SPECT) the authors determined regional cerebral blood flow (rCBF) with inhaled xenon-133, a noninvasive procedure. Studies were performed in 40 normal individuals, and these were compared with rCBF determinations in 51 patients with seizure disorders. Although positive results were obtained in 15 of 16 patients with mass lesions, the ...

متن کامل

A clinical comparison of Xe-127 and Xe-133 for ventilation studies.

Xenon-133 and xenon-127 were compared by performing ventilation studies with both radionuclides in 19 patients with a variety of lung diseases. Assessment of the counting rate over the chest, relative to the radioactivity in the lungs, permitted the evaluation of each isotope in terms of usable photons detected by a scintillation camera with a large field of view and appropriate collimation. A ...

متن کامل

Validation of use of xenon 133 to measure intrarenal distribution of blood flow.

BLAUFOX, M. DONALD, ARTHUR FROMOWITZ, ALAN GRUSKIN, CHIEN-HSING MENG, AND MILTON ELKIN. Validation of use of xenon 133 to measure intrarenal distribution of blood flow. Am. J. Physiol. 219(Z) : 440-444. 1970.-The gamma camera has been used to evaluate the distribution of radioxenon in man after injection into the renal artery. Combined gas-washout curves performed according to the method of Tho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stroke

دوره 1 1  شماره 

صفحات  -

تاریخ انتشار 1970