Rapid 3D-Sodium MRI of Knee Joint In-vivo at 7T
نویسندگان
چکیده
Introduction Loss of glycosaminoglycans (GAG) is a signature of early osteoarthritis (OA). Although sodium MRI has been shown to correlate linearly with GAG concentration (1, 2), it poses major challenges at clinical magnetic field strengths (1.5T/3.0T) in terms of low signal-to-noise (SNR), poor spatial resolution and long acquisition times due to low natural abundance, low sodium concentration and non-vanishing residual quadrupolar interaction results in rapid bi-exponential signal T2 decay when compared to proton MRI. High and ultra high field systems (4.0T-9.4T) with improved gradient hardware and pulse sequences have potential in improving the spatial-temporal resolution of sodium MRI of knee in vivo in clinically acceptable scan times. Therefore, the aim of this study was to demonstrate the feasibility of acquiring high resolution, isotropic 3D-sodium MRI of whole knee joint in less than 15 minutes at 7T via 3D-radial acquisition with ultra short echo times.
منابع مشابه
In vivo high-resolution MRI (7T) of femoro-tibial cartilage changes in the rat anterior cruciate ligament transection model of osteoarthritis: a cross-sectional study.
OBJECTIVE To assess OA-related changes in mean compartmental femorotibial cartilage thickness in rat knees by three-dimensional (3D) MRI (7T). METHODS MRI was performed in vivo at 7T on OA and untouched contralateral knee joints. Gradient Echo Fast Imaging 3D MR images were acquired sequentially in surgically induced OA (D0) in 40 Wistar rats (anterior cruciate ligament transection). Mean fem...
متن کاملChanges of the Patellar Tendon Moment arm Length in Different Knee Angles: A Biomechanical in Vivo Study
Patellar tendon moment arm length (PTma) changes at different knee flexion angles have not been determined in invivo studies. We aimed to determine PTma in four different knee angles using Magnetic Resonance Imaging (MRI) topredict in vivo changes in the moment arm length from different knee angles during running.PTma was measured as the perpendicular distance from muscle–tend...
متن کاملHigh Resolution T1ρ Mapping of In Vivo Human Knee Cartilage at 7T
PURPOSE Spin lattice relaxation time in rotating frame (T1ρ) mapping of human knee cartilage has shown promise in detecting biochemical changes during osteoarthritis. Due to higher field strength, MRI at 7T has advantages in term of SNR compared to clinical MR scanners and this can be used to increase in image resolution. Objective of current study was to evaluate the feasibility of high resolu...
متن کاملHigh resolution in-vivo measurement of sodium T1 of human knee cartilage
Introduction: Sodium MRI is a promising diagnostic technique for assessing cartilage health in-vivo [1]. The measurement of sodium T1 for tissues in the knee is important for the development of simulations modelling the behaviour of sodium and the creation of optimized pulse sequences. T1 differences can be used to suppress fluid signal (akin to FLAIR for H) as has been shown for the brain [2] ...
متن کاملSodium Mri of Articular Cartilage with Improved Snr Using Coherent Ssfp Imaging at 7t
PURPOSE: Sodium (Na) MRI offers direct information on the glycosaminoglycan concentration in cartilage. In vivo Na-MRI, however, is very challenging because of low Na sensitivity, low tissue concentration, and short biexponential transverse relaxation times (T2). Sequences capable of maximizing signal-to-noise ratio (SNR) are therefore highly desirable. Many groups addressed this issue by devel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008