Enhancement of BOLD-contrast sensitivity by single-shot multi-echo functional MR imaging.

نویسندگان

  • S Posse
  • S Wiese
  • D Gembris
  • K Mathiak
  • C Kessler
  • M L Grosse-Ruyken
  • B Elghahwagi
  • T Richards
  • S R Dager
  • V G Kiselev
چکیده

Improved data acquisition and processing strategies for blood oxygenation level-dependent (BOLD)-contrast functional magnetic resonance imaging (fMRI), which enhance the functional contrast-to-noise ratio (CNR) by sampling multiple echo times in a single shot, are described. The dependence of the CNR on T2*, the image encoding time, and the number of sampled echo times are investigated for exponential fitting, echo summation, weighted echo summation, and averaging of correlation maps obtained at different echo times. The method is validated in vivo using visual stimulation and turbo proton echoplanar spectroscopic imaging (turbo-PEPSI), a new single-shot multi-slice MR spectroscopic imaging technique, which acquires up to 12 consecutive echoplanar images with echo times ranging from 12 to 213 msec. Quantitative T2*-mapping significantly increases the measured extent of activation and the mean correlation coefficient compared with conventional echoplanar imaging. The sensitivity gain with echo summation, which is computationally efficient provides similar sensitivity as fitting. For all data processing methods sensitivity is optimum when echo times up to 3.2 T2* are sampled. This methodology has implications for comparing functional sensitivity at different magnetic field strengths and between brain regions with different magnetic field inhomogeneities.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

A novel multi-echo fMRI weighting strategy using principal component analysis for BOLD contrast sensitivity enhancement

Introduction: In functional magnetic resonance imaging (fMRI), acquisition parameters must balance the tradeoffs between spatial coverage and resolution, temporal resolution, and signal contrast. Blood oxygenation level dependent (BOLD) fMRI studies commonly employ a 2D multi-slice T2*-weighted echo-planar imaging (EPI) acquisition to capture changes in T2* decay due to BOLD signal fluctuation,...

متن کامل

Reduced susceptibility effects in perfusion fMRI with single-shot spin-echo EPI acquisitions at 1.5 Tesla.

Arterial spin labeling (ASL) perfusion contrast is not based on susceptibility effects and can therefore be used to study brain function in regions of high static inhomogeneity. As a proof of concept, single-shot spin-echo echo-planar imaging (EPI) acquisition was carried out with a multislice continuous ASL (CASL) method at 1.5T. A bilateral finger tapping paradigm was used in the presence of ...

متن کامل

Parallel Imaging with RASER using Multiband Frequency-modulated Excitation Pulses

Introduction: The recently described RASER sequence is a conceptual novelty in MR imaging [1]. Based on frequency-swept excitation, and timeencoding, RASER is a rapid, pure T2-weighted scheme without signal voids, ghosting and distortion artifacts present in conventional echo-planar imaging (EPI). These properties render it attractive for functional imaging (fMRI). However, in the previous impl...

متن کامل

MR Urography in Patients with Acute Flank Pain: Comparison of Gadolinium-Enhanced 3D FLASH After Low-Dose Diuretic with 2D Turbo Spin Echo Sequences

Introduction: Intravenous excretory urography (IVU) has been regarded as the imaging modality of choice for the detection of urinary tract disorders in patients with acute flank pain. Functional as well as anatomical details are provided by this imaging technique. The use of ionised radiation and contrast material (CM) are considered to be the major drawbacks of IVU. Recently, the use of magnet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 42 1  شماره 

صفحات  -

تاریخ انتشار 1999