The Rutgers Master II-ND Force Feedback Glove
نویسندگان
چکیده
The Rutgers Master II-ND glove is a follow up on the earlier Rutgers Master II haptic interface. The redesigned glove has all the sensing placed on palm support, avoiding routing wires to the fingertips. It uses custom pneumatic actuators arranged in a direct-drive configuration between the palm and the thumb, index middle and ring fingers. The supporting glove used in the RMII design is eliminated, thus the RMII-ND can better accommodate varying hand sizes. The glove is connected to a haptic control interface that reads its sensors and servos its actuators. The interface pneumatic pulse-width modulated servo-valves have higher bandwidth than those used in the earlier RMII, resulting in better force control. A comparison with the CyberGrasp commercial haptic glove is provided.
منابع مشابه
The Rutgers Master II—New Design Force-Feedback Glove
The Rutgers Master II-ND glove is a haptic interface designed for dextrous interactions with virtual environments. The glove provides force feedback up to 16 N each to the thumb, index, middle, and ring fingertips. It uses custom pneumatic actuators arranged in a direct-drive configuration in the palm. Unlike commercial haptic gloves, the direct-drive actuators make unnecessary cables and pulle...
متن کاملVirtual Reality Simulation Modeling for a Haptic Glove
The recent addition of force and touch feedback to Virtual Reality simulations has enhanced their realism. Research on haptics interfaces is now extended to physical modeling of contact surfaces, object hardness, surface deformation, etc.. This is especially needed when dextrous manipulation of virtual objects is concerned. This paper describes a VR system using a haptic glove (Rutgers Master I...
متن کاملPhysically Accurate Haptic Rendering of Elastic Object for a Haptic Glove
This is a final report for the DIMACS grant of student-initiated project. I implemented Boundary Element Method(BEM) using Java. The system is tested with Rutgers Master II haptic glove. This report covers related background research, implementation of BEM and experiment results.
متن کاملShared virtual environments for telerehabilitation.
Current VR telerehabilitation systems use offline remote monitoring from the clinic and patient-therapist videoconferencing. Such "store and forward" and video-based systems cannot implement medical services involving patient therapist direct interaction. Real-time telerehabilitation applications (including remote therapy) can be developed using a shared Virtual Environment (VE) architecture. W...
متن کاملAn Admittance Glove Mechanism for Controlling a Mobile Robot
* Address all correspondence to this author. ABSTRACT This paper presents a bidirectional teleoperation admittance haptic glove (RML glove) which can be used to control mobile robots. The glove receives information from the environment and the internal status of the mobile robot, and generates a force feedback to the operator through the wireless module which in return communicates command sign...