Analysis and perspective of Dosing accuracy and insulin flow rate characteristics of a new disposable insulin pen, FlexTouch, compared with SoloSTAR.

نویسندگان

  • Harold K Yeager
  • Debra A Ignaut
چکیده

Pen injectors for the administration of insulin have been available since the 1980s. The first insulin pen, NovoPen®, was introduced by Novo in 1985 (http://www.novonordisk.com/about_us/history/step-by-step.asp). In the years since, insulin pens have seen innovation in both features and functionality, and many more manufacturers have entered the market. This analysis discusses several features and design alternatives of insulin pens and comments on a new study by Bohnet and coauthors in this issue of Journal of Diabetes Science and Technology that compared the dosing accuracy of the spring-driven FlexTouch® (FT; Novo Nordisk; insulin aspart) with that of the manually operated SoloSTAR® (Sanofi; insulin glulisine). The volumetric flow rate of insulin delivery with FT was also evaluated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosing accuracy and insulin flow rate characteristics of a new disposable insulin pen, FlexTouch, compared with SoloSTAR.

BACKGROUND The introduction of the FlexTouch® (FT; Novo Nordisk; insulin aspart), a prefilled insulin pen with a spring-loaded mechanism, has created more insulin pen options. The present study compared the dosing accuracy of the FT with that of the manually operated SoloSTAR® (SS; Sanofi; insulin glulisine). The volumetric flow rate of insulin delivery with the FT was also evaluated. METHODS...

متن کامل

Dosing Accuracy of Two Disposable Insulin Pens According to New ISO 11608-1

OBJECTIVE The aim was to compare 2 disposable insulin pens, FlexTouch® (Novo Nordisk, insulin aspart) and SoloSTAR® (Sanofi, insulin glulisine), according to new ISO 11608-1:2012 requirements for dosing accuracy. METHODS Sixty pens of each type were tested at 1, 40, and 80 U doses. Following the new ISO requirements, each dose was delivered from the front, middle, and rear one-third of the pe...

متن کامل

Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens

BACKGROUND To deliver insulin glargine 300 U/mL (Gla-300), the widely used SoloSTAR(®) pen has been modified to allow for accurate and precise delivery of required insulin units in one-third of the volume compared with insulin glargine 100 U/mL, while improving usability. Here we compare the accuracy and injection force of 3 disposable insulin pens: Gla-300 SoloSTAR(®), FlexPen(®), and KwikPen™...

متن کامل

Injection force of SoloSTAR® compared with other disposable insulin pen devices at constant volume flow rates.

BACKGROUND Injection force is a particularly important practical aspect of therapy for patients with diabetes, especially those who have dexterity problems. This laboratory-based study compared the injection force of the SoloSTAR® insulin pen (SoloSTAR; sanofi-aventis) versus other available disposable pens at injection speeds based on the delivered volume of insulin released at the needle. M...

متن کامل

United States patient preference and usability for the new disposable insulin device Solostar versus other disposable pens.

The uptake of insulin pen use has been slow in the United States, despite their advantages over the vial/ syringe. We present results of a United States subset of 150 patients with type 1/type 2 diabetes, who were enrolled in an open-label study, that assessed usability, pen features, and patient preferences for four prefilled insulin pens: SoloSTAR, FlexPen, Lilly disposable pen, and a prototy...

متن کامل