A method for increasing jet nebulizer delivery efficiency for aerosol drug delivery in ventilated newborns: an in vitro study.

نویسندگان

  • Michael C Quong
  • Bernard Thébaud
  • Warren H Finlay
چکیده

BACKGROUND A substantial percentage of the aerosol produced by a nebulizer is lost down the expiratory limb of the ventilator circuit. We describe a method for the capture, return, and re-aerosolization of that undelivered aerosol. METHODS We designed an expiratory-limb setup in which an "entraining jet" of gas accelerates unused aerosol and propels it toward an impaction surface. The deposited solution is then returned to the nebulizer reservoir via a feedback tube. As a result, more of the initial dose is delivered to the patient. The fraction of the dose delivered to a filter connected to a passive neonatal test lung was measured with and without the aerosol-recycling components activated. We used a deltaP (difference between the peak inspiratory pressure and the positive-end-expiratory pressure) of approximately 7.5 cm H2O, tidal volume of approximately 6 mL, respiratory rate of 40 breaths/min, and an inspiratory-expiratory ratio of 1:2.3. RESULTS There was a statistically significant improvement with the feedback return to the reservoir, with up to nearly 60% more aerosol delivered. CONCLUSION This improvement in aerosol delivery is encouraging, but more comprehensive studies are needed before such a device could be implemented clinically.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pressurized Metered-Dose Inhalers Versus Nebulizers in the Treatment of Mechanically Ventilated Subjects With Artificial Airways: An In Vitro Study.

BACKGROUND The primary focus of previous aerosol research during mechanical ventilation was the endotracheal tube (ETT). Consequently, there are limited data in the literature on the delivery of inhaled medications administered with different aerosol devices in mechanically ventilated patients with a tracheostomy tube (TT). The purpose of this study was to quantify and compare the efficiency of...

متن کامل

Influence of nebulizer type, position, and bias flow on aerosol drug delivery in simulated pediatric and adult lung models during mechanical ventilation.

BACKGROUND The effectiveness of aerosol drug delivery during mechanical ventilation is influenced by the patient, ventilator, and nebulizer variables. The impact of nebulizer type, position on the ventilator circuit, and bias flow on aerosol drug delivery has not been established for different age populations. OBJECTIVE To determine the influence of nebulizer position and bias flow with a jet...

متن کامل

Physicochemical aspects and efficiency of albuterol nebulization: comparison of three aerosol types in an in vitro pediatric model.

BACKGROUND Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METH...

متن کامل

Overcoming jet lag: optimizing aerosol delivery with and without jet nebulizers.

Early studies have shown that only a small fraction of the nominal nebulizer dose (1–12%) is available for delivery to the lungs in intubated children and adults.1-3 Since then, the characterization of forces governing aerosol delivery in ventilated patients has led to improvements in techniques, and the development of newer aerosol generators with the ability to deliver as much drug to ventila...

متن کامل

High impact aerosol technology offers higher efficiency, but is not ready for prime time.

The therapeutic administration of medical aerosols has been a standard adjunct to treatment of critically ill patients since positive-pressure mechanical ventilators were introduced over 60 years ago, and most ventilators can operate a jet nebulizer in synchrony with mechanically delivered breaths. However, for the first 40 years, little was known about the efficiency of aerosol delivery during...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 51 11  شماره 

صفحات  -

تاریخ انتشار 2006