Improved cerebral microbleeds detection using their magnetic signature on T2*-phase-contrast: A comparison study in a clinical setting

نویسندگان

  • Takoua Kaaouana
  • Anne Bertrand
  • Fatma Ouamer
  • Bruno Law-ye
  • Nadya Pyatigorskaya
  • Ali Bouyahia
  • Nathalie Thiery
  • Carole Dufouil
  • Christine Delmaire
  • Didier Dormont
  • Ludovic de Rochefort
  • Marie Chupin
چکیده

INTRODUCTION/PURPOSE In vivo detection of cerebral microbleeds (CMBs) from T2* gradient recalled echo (GRE) magnitude image suffers from low specificity, modest inter-rater reproducibility and is biased by its sensitivity to acquisition parameters. New methods were proposed for improving this identification, but they mostly rely on 3D acquisitions, not always feasible in clinical practice. A fast 2D phase processing technique for computing internal field maps (IFM) has been shown to make it possible to characterize CMBs through their magnetic signature in routine clinical setting, based on 2D multi-slice acquisitions. However, its clinical interest for CMBs identification with respect to more common images remained to be assessed. To do so, systematic experiments were undertaken to compare the ratings obtained by trained observers with several image types, T2* magnitude, Susceptibility Weighted Imaging reconstructions (SWI) and IFM built from the same T2*-weighted acquisition. MATERIALS/METHODS 15 participants from the MEMENTO multi-center cohort were selected: six subjects with numerous CMBs (20 ± 6 CMBs), five subjects with a few CMBs (2 ± 1 CMBs) and four subjects without CMB. 2D multi-slice T2* GRE sequences were acquired on Philips and Siemens 3T systems. After pilot experiments, T2* magnitude, Susceptibility Weighted Imaging (SWI) minimum intensity projection (mIP) on three slices and IFM were considered for the rating experiments. A graphical user interface (GUI) was designed in order to consistently display images in random order. Six raters of various background and expertise independently selected "definite" or "possible" CMBs. Rating results were compared with respect to a specific consensus reference, on both lesion and subject type points of view. RESULTS IFM yielded increased sensitivity and decreased false positives rate (FPR) for CMBs identification compared to T2* magnitude and SWI-mIP images. Inter-rater variability was decreased with IFM when identifying subjects with numerous lesions, with only a limited increase in rating time. IFM thus appears as an interesting candidate to improve CMBs identification in clinical setting.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SWI or T2*: which MRI sequence to use in the detection of cerebral microbleeds? The Karolinska Imaging Dementia Study.

BACKGROUND AND PURPOSE Cerebral microbleeds are thought to have potentially important clinical implications in dementia and stroke. However, the use of both T2* and SWI MR imaging sequences for microbleed detection has complicated the cross-comparison of study results. We aimed to determine the impact of microbleed sequences on microbleed detection and associated clinical parameters. MATERIAL...

متن کامل

Improved MR imaging detection of cerebral microbleeds more accurately identifies persons with vasculopathy.

BACKGROUND AND PURPOSE The clinical relevance of improved detection of cerebral microbleeds by using advanced-versus-conventional MR imaging techniques remains uncertain. As part of the population-based Rotterdam Scan Study, we compared whether participants whose microbleeds were only demonstrated on a high-resolution MR imaging sequence differed with respect to risk profile and risk of new mic...

متن کامل

Detection of cerebral microbleeds with dual echo T2*-weighted MR imaging at 7.0 Tesla

Introduction Increasing interest in microbleeds had led to an increasing number of studies addressing its prevalence and clinical relevance. Prevalence estimates differ substantially between studies, due to differences in image protocols and field strengths. This study assessed the visualization of cerebral microbleeds with dual echo T2*-weighted imaging at 7.0 Tesla magnetic resonance imaging ...

متن کامل

The Experimental Study of Increased ICP on Cerebral Hemorrhage Rabbits with Magnetic Induction Phase Shift Method

Introduction Measuring magnetic induction phase shift (MIPS) changes as a function of cerebral hemorrhage volume has the potential for being a simple method for primary and non-contact detection of the occurrence and progress of cerebral hemorrhage. Our previous MIPS study showed that the intracranial pressure (ICP) was used as a contrast index and found the primary correlation between MIPS and...

متن کامل

Cerebral microbleeds on MR imaging: comparison between 1.5 and 7T.

BACKGROUND AND PURPOSE The detection of microbleeds differs strongly between studies, due to differences in scan protocol. This study aims to compare the visualization of microbleeds with 3D T2*-weighted imaging at 1.5T with 3D dual-echo T2*-weighted imaging at 7T. MATERIALS AND METHODS Thirty-four patients (29 male; mean age, 58 ± 12 years) with atherosclerotic disease from the Second Manife...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2017