Haemolysis with Björk-Shiley and Starr-Edwards prosthetic heart valves: a comparative study.
نویسندگان
چکیده
Slater, S. D., Saflam, I. A., Bain, W. H., Turner, M. A., and Lawrie, T. D. V. (1974). Thorax, 29, 624-632. Haemolysis with Bjork-Shiley and Starr-Edwards prosthetic heart valves: a comparative study. A comparison was made of the haemolytic complications in 85 patients with two different types of Starr-Edwards cloth-covered ball and cage prosthesis with those in 44 patients with the Bjork-Shiley tilting disc valve. Intravascular haemolysis, as detected by the presence of haemosiderinuria, occurred significantly less often with the Bjork-Shiley than with the Starr-Edwards valve, the overall incidence with aortic, mitral or multiple replacements being 31%, 15%, and 20% for Bjork-Shiley and 94%, 92%, and 88% for Starr-Edwards valves respectively. There was no significant difference in the frequency of haemolysis between each of the two types of StarrEdwards prosthesis studied at either the aortic (2300 versus 2310 model) or mitral (6300 versus 6310) site. Haemolytic anaemia developed in only one patient with a Bjork-Shiley valve but was
منابع مشابه
Intravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis.
Seventy-four patients with single prosthetic valves (Björk-Shiley or Starr-Edwards) in the mitral or aortic position and 18 controls with rheumatic valvar heart disease were investigated for evidence of intravascular haemolysis. Serum lactate dehydrogenase (LDH) was used as the most sensitive indicator of haemolysis. Raised concentrations were found in a third of 39 patients with Björk-Shiley p...
متن کاملDoppler echocardiographic characteristics of normal and dysfunctioning prosthetic valves in the tricuspid and mitral position.
The Doppler echocardiographic characteristics of 70 prosthetic valves in 35 patients are reported. Twenty nine patients had a Björk-Shiley prosthesis in both mitral and tricuspid positions and six had Carpentier-Edwards valves in both sites. Five of the patients had abnormal tricuspid prostheses on the basis of clinical and echocardiographic criteria. Pulsed wave Doppler echocardiography was us...
متن کاملPrevalence and characteristics of intracranial microemboli signals in patients with different types of prosthetic cardiac valves.
BACKGROUND AND PURPOSE Transcranial Doppler detection of microemboli is widely described, but there is no clear evidence of the clinical significance or nature of the embolic material in vivo. Thromboembolism is a major cause of morbidity in patients with prosthetic cardiac valves. We undertook this study to evaluate the prevalence and the acoustic characteristics of microembolic signals in thr...
متن کاملThirteen year-experience with mitral valve replacement.
At the Niigata University Hospital, various kinds of prosthetic valves such as the Starr-Edwards nonclothand cloth-covered, Bjork-Shiley tilting disc, and Carpentier-Edwards porcine valves, have been used from September, 1965 to March, 1979 for replacement of diseased valves on 176 patients. The patients with Starr-Edwards nonclothand cloth-covered ball valves showed survival rates of 90 and 84...
متن کاملLimitations of Doppler ultrasound in the assessment of the function of prosthetic mitral valves.
Pressure half time has been assumed to be a relatively flow-independent measure of orifice area, but it may also be influenced by atrial and ventricular factors. Pressure half time and peak left ventricular inflow velocity were measured by continuous wave Doppler ultrasound in 164 patients with normally functioning Carpentier-Edwards, Björk-Shiley, and Starr-Edwards mitral prostheses. Pressure ...