Dynamic MRI of the temporomandibular joint at 3 Tesla using a gradient echo sequence
نویسندگان
چکیده
Introduction Temporomandibular joint (TMJ) dysfunction is a cause of headache, facial pain and referred otalgia, which can be quite debilitating to patients. MRI has been applied in limited circumstances to define contours of the articular disc, and to evaluate disc motion during translation of the condyle with opening and closing of the mouth. Broad implementation of an effective protocol has been limited by lack of an effective dynamic imaging sequence having sufficient temporal resolution to evaluate joint space mechanics. Additionally, current protocols are very time intensive, which is limiting for both the patient and busy clinical practices. We seek to introduce a dynamic sequence able to capture both disc motion and contour. Implementing such a protocol may lead to earlier diagnosis and treatment of TMJ dysfunction, ultimately improving patient care. Recent dynamic TMJ studies demonstrated the feasibility of a single-shot spin echo sequence at 1.5 Tesla [1]. In this work, we report our preliminary studies on the feasibility of a real-time gradient echo (GRE) imaging at 3 Tesla.
منابع مشابه
Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)
Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different and weighting for liver fat quantification in patients with...
متن کاملIn-Vitro Evaluation of Pre- and Post-Compression States of Human Articular Cartilage Using MRI at 3 Tesla
The purpose of this study was to evaluate changes of several MR parameters (T1, T2 and ADC) before and after compression in human cartilage samples using unique microimaging compression system. Cartilage samples were prepared from joints of 10 patients, who underwent a total knee joint replacement. Study was performed on a Bruker 3T Medspec whole-body scanner (Bruker, Ettlingen, Germany) using ...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملAccuracy Rate of Clinical Diagnosis of Disc Displacement without Reduction in Temporomandibular Joint Using MRI
Introduction: Internal derangement (ID) of TMJ is the most common type of temporomandibular disorders after muscle disorders and includes all disorders related to incoordination and dislocation of disc and condyle. Anterior disc displacement without reduction or closed lock will happen if the disc or condyle displaces severely or if the disc traps in the space in front of the condyle accompanie...
متن کاملDrug eluting coronary stent: in vitro evaluation of magnet resonance safety at 3 Tesla.
PURPOSE To evaluate MR safety at 3 Tesla for a drug eluting coronary stent. METHODS A drug eluting coronary stent (Endeavor, cobalt alloy, Medtronic Vascular, Santa Rosa, CA) was evaluated for magnetic field interactions, heating, and artifacts at 3 Tesla. MRI-related heating was assessed with the stent in a gelled saline-filled phantom using a transmit/received RF body coil with a whole body...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009