Cerebrovascular reserve in patients with carotid occlusive disease assessed by stable xenon-enhanced ct cerebral blood flow and transcranial Doppler.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Cerebrovascular reserve (CVR) by both transcranial Doppler ultrasonography (TCD) and quantitative cerebral blood flow (CBF) can identify subgroups of patients at increased risk for stroke. A direct comparison of CVR measurements obtained with both technologies in patients with cerebrovascular occlusive disease is lacking. METHODS CVRs before and after acetazolamide administration (1 g IV) were measured by TCD insonation of the middle cerebral artery (MCA) and CBF obtained with stable xenon CT (Xe/CT) in 38 patients with carotid occlusive disease. Sensitivity/specificity calculations were based on 2 Xe/CT MCA values: an average over 4 levels and the level with the lowest percent change in CBF. Compromised CVR was defined as no reactivity or a decrease in reactivity. RESULTS Using the analysis of the systolic TCD, we found that velocity changes compared with the average Xe/CT MCA CVR showed a sensitivity of 33%, specificity of 90.6%, positive predictive value of 54.5%, and negative predictive value of 80%. The sensitivity of TCD compared with the lowest Xe/CT CBF CVR was 35.5%, specificity and positive predictive values were 100%, and negative predictive value was 66.7%. The index of validity was between 72% and 76%. CONCLUSIONS TCD is much less sensitive than Xe/CT CBF in identifying patients with compromised CVR. This may be a result of the inability of TCD to identify patients with compromised reserves when their MCA blood flow comes from collateral sources. The lack of correlation between TCD and Xe/CT CBF for identifying patients with compromised CVR should be considered when stroke risk assessments are made by TCD.
منابع مشابه
A simple test to assess cerebrovascular reserve capacity using transcranial Doppler sonography and acetazolamide.
The goal of this study was the development of a simple bedside test to assess cerebrovascular reserve capacity using transcranial Doppler sonography. We studied 33 normal persons at rest and after stimulation of cerebral blood flow with 1 g acetazolamide. Their mean +/- SD increase in blood flow velocity in 54 middle cerebral arteries 10 minutes after stimulation was 24.4 +/- 9.2 cm/sec. We tri...
متن کاملStable xenon CT cerebral blood flow imaging: rationale for and role in clinical decision making.
The stable xenon CT method of measuring cerebral blood flow has been investigated in research studies for over 10 years. Recently, it has been gaining clinical acceptance, primarily owing to a combination of several unique advantages it holds over other cerebral blood flow measurement techniques. The accuracy of this technique in quantifying low cerebral blood flow gives it a unique application...
متن کاملOriginal Contributions Clinical and Hemodynamic Aspects of Low-Flow Infarcts
We used single-photon emission computed tomography to measure cerebral blood flow, cerebral blood volume, and cerebral perfusion reserve and transcranial Doppler sonography with CO, stimulation to assess hemispheric vasomotor reactivity in 37 patients and in normal controls. Computed tomography and magnetic resonance imaging were performed to differentiate morphologically low-flow infarcts (n=1...
متن کاملCerebral hemodynamic in patients with major β-Thalassemia using transcranial Doppler sonography
Background: β-thalassemia, a severe form of anemia, is an inherited blood disorder characterized by growth retardation, splenomegaly, and bone abnormalities. Complications related to treatment-induced iron overload also affect the quality of life of patients with major β-thalassemia. Some recent studies indicated cerebral hemodynamic disorders and increased risk of stroke in these patients. The...
متن کاملBalloon test occlusion of the internal carotid artery: change in stump pressure over 15 minutes and its correlation with xenon CT cerebral blood flow.
PURPOSE To determine whether stump pressure changes significantly over time during temporary internal carotid artery (ICA) occlusion via an endovascular balloon, and to examine correlations between stump pressure changes and cerebral blood flow (CBF) as measured by xenon CT. METHODS Seventy candidates for ICA sacrifice were evaluated preoperatively with a test occlusion of the cervical ICA us...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stroke
دوره 32 8 شماره
صفحات -
تاریخ انتشار 2001