Artificial eye for scotopic vision with bioinspired all-optical photosensitivity enhancer.
نویسندگان
چکیده
The ability to acquire images under low-light conditions is critical for many applications. However, to date, strategies toward improving low-light imaging primarily focus on developing electronic image sensors. Inspired by natural scotopic visual systems, we adopt an all-optical method to significantly improve the overall photosensitivity of imaging systems. Such optical approach is independent of, and can effectively circumvent the physical and material limitations of, the electronics imagers used. We demonstrate an artificial eye inspired by superposition compound eyes and the retinal structure of elephantnose fish. The bioinspired photosensitivity enhancer (BPE) that we have developed enhances the image intensity without consuming power, which is achieved by three-dimensional, omnidirectionally aligned microphotocollectors with parabolic reflective sidewalls. Our work opens up a previously unidentified direction toward achieving high photosensitivity in imaging systems.
منابع مشابه
Study of Optical Models Regarding the Human Eye
Introduction: Until now, many models have been presented for optical study of the human eye. In recent years, surgery on the anterior section of the eye (such as cataract and photo-refractive surgery) has increased, so a study on the optics of the eye and evaluation of vision quality has become more important. Material and Methods: In this article, some of these models are considered. They incl...
متن کاملRetinal specific measurement of dark-adapted visual function: validation of a modified microperimeter
BACKGROUND Scotopic function is an important marker of many retinal diseases and is increasingly used as an outcome measure in clinical trials, such as those investigating gene therapy for Lebers congenital amaurosis. Scotopic visual function has traditionally been measured using an adapted perimetry system such as the Humphrey field analyser (HFA). However this system does not control for fixa...
متن کاملScotopic and Photopic Microperimetry in Patients With Reticular Drusen and Age-Related Macular Degeneration.
IMPORTANCE Clinical observations suggest that patients with age-related macular degeneration (AMD) have vision problems, particularly in dim light conditions. Previous studies on structural-functional analysis in patients with AMD with reticular drusen (RDR) have focused on photopic sensitivity testing but have not specifically assessed scotopic function. OBJECTIVE To evaluate retinal functio...
متن کاملRetinal specific measurement of dark-adapted visual function: A validation study
Background: Scotopic function is an important marker of many retinal diseases and is increasingly used as an outcome measure in clinical trials, such as those investigating gene therapy for Lebers congenital amaurosis. Scotopic visual function has traditionally been measured using an adapted perimetry system such as the Humphrey field analyser (HFA). However this system does not control for fix...
متن کاملIndividual Differences in Scotopic Visual Acuity and Contrast Sensitivity: Genetic and Non-Genetic Influences
Despite the large amount of variation found in the night (scotopic) vision capabilities of healthy volunteers, little effort has been made to characterize this variation and factors, genetic and non-genetic, that influence it. In the largest population of healthy observers measured for scotopic visual acuity (VA) and contrast sensitivity (CS) to date, we quantified the effect of a range of vari...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Proceedings of the National Academy of Sciences of the United States of America
دوره 113 15 شماره
صفحات -
تاریخ انتشار 2016