Comparison of the Sensitivity of QuantiFERON-TB Gold In-Tube and T-SPOT.TB According to Patient Age
نویسندگان
چکیده
Currently, there are two types of interferon-gamma release assays (IGRAs) in use for the detection of tuberculosis (TB) infection, the QuantiFERON-TB Gold In-Tube test (GFT-GIT) and T-SPOT.TB. Owing to contradictory reports regarding whether the results of these IGRAs are affected by the age of the patient, we aimed to determine if these two tests have age-related differences in sensitivity. We retrospectively reviewed the medical records of diagnosed TB patients who were tested using either QFT-GIT or T-SPOT.TB from February 2008 to December 2013. The positivity of the two tests was analyzed and compared with true TB infection, which was defined as active TB based on either a positive Mycobacterium culture or a positive TB polymerase chain reaction. The QFT-GIT group included 192 TB patients, and the T-SPOT.TB group included 212 TB patients. Of the patients with pulmonary TB, 76 (39.6%) were in the QFT-GIT group and 143 (67.5%) in the T-SPOT.TB group. The overall sensitivity was 80.2% for QFT-GIT and 91.0% for T.SPOT.TB. The sensitivities of QFT-GIT and T-SPOT.TB according to age group were as follows: <29 years, 93.3% and 96.7%; 30-49 years, 86.5% and 94.7%; 50-69 years, 76.8% and 87.5%; and >70 years, 68.3% and 85.7%, respectively. The trend of age-related changes in sensitivity was significant for both QFT-GIT (p = 0.004) and T.SPOT.TB (p = 0.039). However, only QFT-GIT was significantly related to age in the multivariate analysis. QFT-GIT, but not T-SPOT.TB, was significantly affected by patient age.
منابع مشابه
Quantitative lung T cell responses aid the rapid diagnosis of pulmonary tuberculosis.
BACKGROUND The diagnosis of smear-negative pulmonary tuberculosis (TB) is problematic. There are limited data on the profile of alveolar TB antigen-specific T cells, and their utility for the rapid immunodiagnosis of pulmonary TB is unclear. METHODS Antigen-specific interferon gamma (IFNgamma) responses to the RD-1 antigens ESAT-6 and CFP-10 (T-SPOT.TB and QuantiFERON-TB-Gold-In-Tube), hepari...
متن کاملComparison of two interferon-gamma release assays (QuantiFERON-TB Gold In-Tube and T-SPOT.TB) in testing for latent tuberculosis infection among HIV-infected adults
There is currently no 'gold standard' for diagnosis of latent tuberculosis infection (LTBI), and both the tuberculin skin test and interferon-gamma release assays (IGRAs) are used for diagnosis; the latter have a higher sensitivity than tuberculin skin tests for diagnosis of LTBI in HIV-infected individuals with lower CD4 counts. No evidence base exists for selection of IGRA methodology to iden...
متن کاملAccuracy of Immunodiagnostic Tests for Active Tuberculosis Using Single and Combined Results: A Multicenter TBNET-Study
BACKGROUND The clinical application of IFN-gamma release assays (IGRAs) has recently improved the diagnosis of latent tuberculosis infection. In a multicenter study of the Tuberculosis Network European Trialsgroup (TBNET) we aimed to ascertain in routine clinical practice the accuracy of a novel assay using selected peptides encoded in the mycobacterial genomic region of difference (RD) 1 for t...
متن کاملUse in routine clinical practice of two commercial blood tests for diagnosis of infection with Mycobacterium tuberculosis: a prospective study.
BACKGROUND Two commercial blood assays for the diagnosis of latent tuberculosis infection--T-SPOT.TB and QuantiFERON-TB Gold--have been separately compared with the tuberculin skin test. Our aim was to compare the efficacy of all three tests in the same population sample. METHODS We did a prospective study in 393 consecutively enrolled patients who were tested simultaneously with T-SPOT.TB an...
متن کاملSystematic review: T-cell-based assays for the diagnosis of latent tuberculosis infection: an update.
BACKGROUND Interferon-gamma-release assays (IGRAs) are alternatives to the tuberculin skin test (TST). A recent meta-analysis showed that IGRAs have high specificity, even among populations that have received bacille Calmette-Guérin (BCG) vaccination. Sensitivity was suboptimal for TST and IGRAs. PURPOSE To incorporate newly reported evidence from 20 studies into an updated meta-analysis on t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2016