Inherent insensitivity to RF inhomogeneity in FLASH imaging.

نویسندگان

  • Danli Wang
  • Keith Heberlein
  • Stephen LaConte
  • Xiaoping Hu
چکیده

Radiofrequency (RF) field inhomogeneity is an unavoidable problem in MRI, and it becomes severe at high magnetic fields due to the dependence of B1 on the sample. It leads to nonuniformities in image intensity and contrast, causing difficulties in quantitative interpretation and image segmentation. In this work, it is observed that with the fast low-angle shot (FLASH) sequence, which is often used for anatomic imaging and morphometric studies, sensitivity to RF inhomogeneity can be substantially reduced when the same coil is used for both transmission and reception, and an appropriate nominal flip angle is employed. This observation can help us understand the signal behavior of FLASH in the presence of RF inhomogeneity, and provide a guide for selecting parameters in FLASH imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inherent insensitivity to B1 field inhomogeneity using regularized nonlinear inversion reconstruction

INTRODUCTION Signal intensity variation that arises from inhomogeneous transmit and receive fields not only complicates the qualitative appearance of MR images but also presents the major source of error in quantitative MRI/S. Many current approaches address this problem by mapping the transmit field [1] and assuming the same transmit and receive field patterns during compensation [2]. However,...

متن کامل

Saturation-recovery Snapshot Flash Reduces Rf Pulse Angle Inhomogeneity Artefacts in Dce-mri of the Breast at 3t

INTRODUCTION Radiofrequency (RF) pulse angle inhomogeneity is a significant problem in breast MRI at 3T. Dynamic contrast-enhanced (DCE)-MRI of the breast with FLASH is susceptible to this RF inhomogeneity, and results in errors in the measurement of tumour enhancement ratio (ER) [1], where ER is a function of changes in relaxation rate (ΔR1) and represents contrast agent concentration in the t...

متن کامل

FIELD INHOMOGENEITY COMPENSATION IN HIGH FIELD MAGNETIC RESONANCE IMAGING (MRI) by

FIELD INHOMOGENEITY COMPENSATION IN HIGH FIELD MAGNETIC RESONANCE IMAGING (MRI) Zhenghui Zhang, PhD University of Pittsburgh, 2006 This thesis concentrates on the reduction of field (both main field B0 and RF field B1) inhomogeneity in MRI, especially at high B0 field. B0 and B1 field inhomogeneity are major hindrances in high B0 field MRI applications. B1 inhomogeneity will lead to spatially v...

متن کامل

Quantitative T(1)(ρ) imaging using phase cycling for B0 and B1 field inhomogeneity compensation.

T(1)(ρ) imaging is useful in a number of clinical applications. T(1)(ρ) preparation methods, however, are sensitive to non-uniformities of the B0 magnetic field and the B1 RF field. These common system imperfections can result in image artifacts and quantification errors in T(1)(ρ) imaging. We report on a phase-cycling method which can eliminate B1 RF inhomogeneity effects in T(1)(ρ) imaging. T...

متن کامل

High-Resolution T2 FMRI at High Magnetic Fields Using PSIF

At very high magnetic fields such as 7 Tesla, it is expected that imaging techniques that take advantage of the Tz BOLD effect will produce activation maps more specific and better localized to actual sites of neuronal activation than those arising from the T; BOLD effect. In this work, the PSIF (gradient-reversed FISP, SSFP, CE-FAST) sequence is used as such a technique because it is particula...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 52 4  شماره 

صفحات  -

تاریخ انتشار 2004